ABS 100 Installation And Operating Instructions Manual - page 9
ABS lifting station Piranhamat
ABS lifting station Piranhamat
4.1.
V
The venting and aeration of the unit can take place into a room via the activated carbon filter with overflow
prevention supplied as standard. A separate vent line (external diameter 25 mm) brought above roof level may
be fitted. This is done by removing the screen and inserting a pipe.
4.1.3
C f w h-h b , b h w
A wash-hand basin or shower is connected by pressing the inflow line (3) into the push-in seal of the upper inlet
opening (1) after removal of the plug. Make certain that it is pushed fully home.
ATTENTION
The push-in seal must be inserted in such a manner that the pipe retaining shoulder
as well as the printed letters “OBEN” point upwards.
1
Inflow opening upper. (In
some prototype models this
is only on the left hand side of
the tank.)
11
10-00
2 Push in seal.
3
Inflow DN 40.
4 Piranhamat 100/120..
Figure 8 Connection of an inflow line DN40
ATTENTION
If exchanging a Piranhamat 100/120 of the new series for one of the older Piranhamat
models we recommend that you use the version part no. 07560320/07565092 with the
lower opening.
See note under 1.2.1
4.
E C
c
Before commissioning an expert should check that one of the necessary electrical protective devices
is available. Earthing, neutral, earth leakage circuit breakers, etc. must comply with the regulations
of the local electricity supply authority and a qualified person should check that these are in perfect
order.
ATTENTION
The power supply system on site must comply with VDE or other local regulations
with regard to cross-sectional area and maximum voltage drop. The voltage stated on
the nameplate must correspond to that of the mains
This unit must be connected to a mains switch which isolates all poles.
All relevant safety regulators as well as general good technical practice must be complied with.
The unit is supplied ready for installation. An earthed socket (in accordance with VDE / Electrical Supply Board
guidelines) installed in a correct manner is all that is required.
ATTENTION
The Piranhamat 100/120 unit should not be placed in a position where excessive
steam or flooding of the complete unit may occur. Should this occur please have the
unit thoroughly checked before use.
ATTENTION
The earthed socket should comply with the relevant regulations.
NOTE
Please consult your electrician.