Abt 2 BEAMS Installation Manual - page 4
6
Setting of transmitter data
1 2 3 4
Frequencies selection
3
Power
Power
OFF
ON
OFF
ON
Tamper
Tamper
7
7
8
8
1
1
2
2
3
3
4
4
5
5
6
6
NC
NC
Frequency list
DIP
1
2
3
4
5
6
7
8
1
2
3
ON
OFF
ON OFF
ON OFF ON OFF
OFF
ON
ON OFF OFF
ON
ON OFF
OFF
OFF OFF OFF
ON
ON
ON
ON
Empty
240
240
50
50
Response time adjustment
Response time adjustment
Trouble
Trouble
Power
Power
Alarm
Alarm
Tamper
Tamper
7
7
8
8
9
9
10
10
12
12 11
11
1
1
2
2
3
3
4
4
5
5
6
6
OFF
ON
OFF
ON
DIP
15mm
Programming switch
7
Setting of receiver data
Receiver adopts electronic memory chip to store data,so it is not with DIP switch. Setting of receiving frequency and NO/NC.
7.1
Status shift diagram
Keep pressing the tamper for
3 times within 3 seconds, wh-
en there are beep beep..
sound for tow times, it enters
to parameter setting status.
Enter status of receiving frequency bands and NO/NC
Alarm light (siren): send out sound 2 times
periodically, at this time, LED4 displays
NO/NC, LED3-LED1 display receiving bands.
Each receipt, the function switch LED4-LED1
add address 1 and auto re-circle.
If function switch is not operated over 10 seconds
Working status
Non-alarm: alarm light
NC, siren no sound
Alarm: alarm light NO,
siren keep sounding.
7.2
Setting diagram for receiver
bands and alarm relay NC/NO.
Press programming switch in 3 secretary
1
2
3
4
5
6
7
8
1
8
0 0 0
4 3 2 1
Signal
LED
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
0 0 0
1 1 1
Note
1=NO 0=NC
1.Remove the cover
2.Attach the paper stencil onto the location
where the equipment is to be mounted, and
drill the holes in the positions on its mark.
3.Put the cable through the
hole for wiring.
4.Fix the main body onto the wall
5.Connect the cable to the wire terminal.
.Setting procedure
Wiring hole
TRANSMITTER
RECEIVER
TRANSMITTER
Frequen
cies
During operation status, press the tamper switch by 3 times within 3 seconds, when there are two long beep sound, it ent-
ers to parameter setting status, in this status, siren and alarm light will send out 1 sounds periodical-ly in order to mention
that it is in the part of parameter setting.
ON/OFF Signal strength indicator
One long beep sound means setting is ended and
automatic memory finished, returns to working status.
Bands
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
Note: when power is supplied, equipment address and frequency bands setting data for 10
seconds automatically, and alarm light (siren) will offer relevant indication. And then
it enters to operation status.