AccuPower AccuManager 807 Operating Manual - page 13
After setting the current and voltage press
Start/Enter key for more than 3 seconds to start the
process.
(Charge current:0.1~7.0A, Volatge:1~8series)
This shows the number of cells you set up and the
processor detects. ‘R:’ shows the number of cells
found by the charger and ‘S:’ is the number of cells
selected by you at the previous screen. If both
numbers are identical you can start charging by
press Start/Enter button. If not, press Batt
type/Stop button to go back to previous screen.
Then carefully check the number of cells of the
battery pack to charge again.
The screen shows the present situation during
charge process. To stop charging press Batt
type/Stop key once.
‘FAST’ charging Lithium battery
The charging current is getting smaller as the process goes to the near end term
of Lithium battery charging. To finish charging process earlier, this program
eliminate certainterm of CV process. Actually, the charging current will goes to 1/5
from the initial value to end the process while the normal charging goes to 1/10
during CV term. The charging capacity may be a bit smaller than normal charging
but the process time will be reduced.
You can set up the charging current and the
voltage of the battery pack being charged. As you
press Start/Enter button the voltage confirmation
will be displayed. And then, if you confirm the
voltage and current, press Start/Enter button again
to start charging.
This shows the present state of ‘ FAST’
charging.
To stop charging arbitrary, press Batt type/Stop key
once.