AccuPower AccuManager 807 Operating Manual - Nimh/nicd Battery Program
Voltage balancing and monitoring during the discharge
The processor monitors the voltage of individual cells during ‘storage-mode’
and ‘discharge’ of Lithium battery pack. It tries to normalise the voltages to
be equal. For this feature, the individual plug of the battery pack should be
connected to the individual port of the charge.
If the voltage of any one or more cells varies abnormally during the
procedure. AP807 terminates the process forcibly with the error massage. If this
happens, the battery pack contains the bad cell, or the bad connection of
the cable plug. You can easily know which one cell is bad by pressing INC
button at time of showing the error message.
The processor found that the voltage of one
of the cell in the Lithium battery pack is too
low.
In this case, the 4th cell is bad. If there
happens the connection-break of the cable
or pulg, the voltage value may show zero.
These programs are for charging or discharging NiMH
(Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium) battery commonly used
for R/C model aplications. To alter the value at the display, press
Start/Enter key to make it blink then change the value using INC or DEC
key. The value will be stored by pressing Start/Enter key once.
To start the precess, press Start/Enter button for more than 3 seconds.
This program simply charger the battery
using the current you set. In ‘Aut’ mode, you
need to set the upper limit of charge current
to avoid from higher feeding current that may
damage the battery. Bacause some
batteries of low