AIRLESSCO 1200G Service & Operation Manual - Introduction
2
3
This gas powered airless sprayer is built
tough to take the day after day high
volume demands of contractors. The
paint pump features a large stainless
steel, severe duty, slow-stroking piston,
and Airlessco's pat ent ed sta tion ary
triple-life packing. This product is
"Built
to Perform...Built to Last" using the
latest tech nol o gy in pump de sign for
smooth op er a tion and low maintenance.
INTRODUCTION
5. Storage
Oil-base paint: Flush with mineral spirits.
Water-base paint: Flush with water, then min er al
spirits and leave the pump, hose and gun filled
with mineral spirits.
For longer storage, use mixture of mineral spirits
and motor oil (half & half). Shut off the sprayer,
follow Pressure Relief Procedure on page 6 to
relieve pressure and make sure prime valve is left
open.
6. Start up after storage
Before using water-base paint, flush with soapy
water and then a clean water fl ush.
When using oil-base paint, flush out the mineral
spirits with the material to be sprayed.
SPECIFICATIONS
AIRLESSCO SL6200, ALLPRO 1200G
Pressure
0 - 3000 psi
Output
1.5 gpm, 5.7 Ltr./Min.
Tip size
1 gun up to 0.041"
2 guns up to 0.028"
Engine
5.5 hp Honda
FLUSHING - Read Prior to Using Your Sprayer
1. New sprayer
Your unit was factory tested in an anti-freeze
solution which was left in the pump. Before
using oil-base paint, fl ush with mineral spirits only.
Before using water-base paint flush with
mineral spirits, followed by soapy water, then
a clean water fl ush.
2. Changing colors
Flush with a compatible solvent such as
mineral spirits or water.
3. Changing from water-base to oil-base paint
.
Flush with soapy water, then mineral spirits.
4. Changing from oil-base to water-base paint.
Flush with mineral spirits, followed by soapy
water, then a clean water fl ush.
NO MODIFICATIONS or alterations of any AIRLESSCO Equipment or part is allowed.
HANDLE THIS UNIT AS YOU WOULD A LOADED FIRE ARM!
High Pressure Spray Can Cause Extremely Serious Injury.
OBSERVE ALL WARN INGS!
Before operating this unit, read and follow all safety warnings and in struc tions
related to the usage of this equipment. READ and LEARN the warnings on pages
4, 5, 6, & 7 and FOLLOW the Pressure Relief Pro ce dure on Page 6.
All Service Procedures to be performed by an Authorized Airlessco Service Center ONLY.
IMPORTANT WARNING !!