Airmar H2183 Owner's Manual & Installation Instructions - page 13
13
NOTE 1: The sensor must be supplied with 12 VDC (±3 VDC) at 0.5 amp.
NOTE 2: If your display does not have NMEA 0183 output connections, the yellow
and orange wires are not needed and their ends should be taped separately.
(Alternatively, yellow and orange wires can be connected to an external sensor.)
NOTE 3: The display power may be wired directly to the sensor cable, or it may be
wired separately.
No Connector
—
Wiring
1. Allowing an extra 25 cm (10") for wiring ease, cut the cable to length.
2. Strip 60mm (2-1/2") of the outer jacket and foil shielding from the cut end of the
cable (see Figure 4).
3. Strip 10 mm (3/8") of conductor insulation from the end of each colored wire.
4. Protect the cable’s foil shielding from causing a short by using heat-shrink
tubing around the jacket where the wires emerge from the cable. The tubing
must overlap the wires a minimum of 6mm (1/4").
5. Connect the wires to the display (see Figure 5).
6. Fasten all cable in place.
7. Your installation is complete. To begin receiving data, refer to the owner’s
manual that came with your display.
Figure 5. NMEA 0183 cable
Copyright © 2008 Airmar Technology Corp.
sensor connector
BARE
NMEA 0183 display