12. TROUBLESHOOTING
Display report
Possible cause
Action
F1 Drip tray full
Drip tray is full
Empty the drip tray, message disappears
Boiler is warming up or has
reached the min. boiler
temperature.
The message disappears when the boiler
has reached the set temperature
F2 Heating
Boiler is not heating up.
Temperature safety feature is
switched off.
Reset the temperature safety feature on the
back. Check whether the boiler must be de-
scaled, de-scale if necessary.
During start-up – boiler is empty
and being filled.
No action required. When the boiler has
reached the correct level this is followed by
F2 Warm up.
F3 Filling
During use - boiler is filling too
slowly. After approximately 3
minutes F3 changes to E3
Check the water pressure. Open the water
supply valve completely and check the
connection hose for kinks.
Display report
Possible cause
Action
B0
Temperature sensor problem in the
hot water system
Call the dealer or service engineer.
B1
Temperature sensor problem in the
hot water system
Call the dealer or service engineer.
E0
Problems with the temperature
regulation in the hot water system
Call the dealer or service engineer.
E1
Problems with the temperature
regulation in the hot water system
Call the dealer or service engineer.
E3
Hot water system is filling too slow.
The inlet valve is closed for safety.
Check the water pressure. Open the water
supply and check the connection hose for
kinks. Switch the machine off and then on
again.
E7
Minimum electrode fault .
Call the dealer or service engineer.
Problem
Check
Machine is not
working
- fuses (group box)
- main switch (group box)
- main lead plug
Machine is not
responding
- machine in standby position
Flavour problems:
- top up ingredient holder(s)
- position ingredient holder(s) correctly
- ingredient holder(s) outlet bend(s) blocked
- dosing pipe in ingredient holder loose or damp
- ingredient divider in ingredient holders not working
- wrong product type
- mixer fouled
- products damp, check the ventilation system and replace product(s)
- product(s) aged; replace product(s)
- boiler temperature too low; inform your supplier