Antari HZ-500 User Manual - page 4
and prevent the clogging problem of hazers.
3.If you have followed the above operation steps, and you still experience low
output, mechanical noise or no output at all, unplug the unit immediately
from the mains. Check the fluid level, the external fuse, the remote control
connection, and the power cable from the wall. If all of the above appears to
be O.K., plug the unit in again. If the hazer still does not function,
discontinue operation or it may result in permanent damage to the unit.
Return the machine to your Antari dealer. Always drain tank before mailing
or transporting this unit.
4. Please detach the cap on the tank if you want to clean the cap.
Do not wipe it directly when the cap is attached on the tank.
By doing this you can avoid the dust fall into the fluid tank and contaminate
the haze liquids.
5.Please do not allow magnetic equipments to be close to the haze outlet door
of hazer. Magnetic equipment could cause wrong action of the door sensor.
There are 6 buttons on the control panel. They are Function
, Timer
, Up
, Down
, Volume
and Manual
respectively.
The function and operation of the controller is as following:
1.When switching the HZ-500 on, the characters, Ready To Haze, will be
displayed on the LCD screen. Pressing Volume
button once can
activate the hazer and the LCD screen will display “Working”. Press the
Volume
button again will cease hazing and the LCD screen will
display “Ready To Haze”. Under Ready To Haze mode, to keep pressing
Manual
button can make the hazer produce haze(LCD screen shows
“Working”) while releasing Manual
button will stop hazing(LCD screen
shows “Ready To Haze”). Finally, under this mode, press Timer button, the
timer will be triggered.
2.When the unit is under Ready To Haze state, press the Function
button once, the LCD screen shows Interval Set. Use Up
and Down
button to adjust the interval of timer, which can be set from 1 to 200
seconds.
3.When the unit is under Ready To Haze state, press the Function
button twice, the LCD screen shows Duration Set. Use Up
and Down
button to adjust the duration of timer, which can be set from 1 to 200
seconds.
-Control Panel Operation
MANUAL
MANUAL
MANUAL
English 03