B&K AV100.2 User Manual - Dip Switches
11
DIP Switches
Each amplifier has a set of DIP Switches used for configuration purposes. The
function of each is described below:
RJ-45 I/O - When using the RJ-45 Inputs and Outputs, the DIP
switch would be enabled as shown to send a trigger signal. Also,
when using the control trigger through RJ-45, the CTRL I/O DIP
switch would have to be enabled as shown.
MONO—Amplifiers with the MONO DIP switch set to ON will have
the sum of the selected audio inputs processed into a single mono
source for both inputs. When mono is not desired, or independent
channel amplification is necessary, the MONO switch must be set to
OFF.
SENSE - The amplifier will sense an audio signal from the RCA Au-
dio inputs or from the RJ-45 inputs. The Amp Status LED will turn
off when no audio signal is detected and turn green when detecting an
audio signal from either input.
CTRL IN - When a trigger is needed to take the amplifier in and out
of standby state, the CTRL IN DIP switch would be enabled. This
applies to both the 1/8” minijack control input and RJ-45 control in-
put. Thebrick amplifiers require at least 4VDC and require less than
1mA of current of trigger signal.
Note: The ON (enabled) position would be in the DOWN position on
the AV Brick Amplifiers. To disable the function, the DIP switch would be in
the UP position.
Faceplate Options
There are a few faceplate options for connecting multiple AV brick amplifiers
to fit in a rack space.
2U Brick Amplifier Mounting Plate - 3.5” by 19” Faceplate to mount up to 3
AV brick amplifiers
4U Brick Amplifier Mounting Plate - 7” by 19” Faceplate to mount up to 6
AV brick amplifiers
Wall Mounting Bracket - mount an AV brick amplifier from either the left or
right side
To change the faceplate on the AV brick amplifiers, use a 1/8” hex screwdriver.