B&K CK1.2 Manual To Installation - Page 10
Page 10
S
B
I M P LY
E T T E R !
B K
&
Connecting A Local TV or Device
Every keypad can control a local TV or even a local system of components
in addition to the components in the main system. A two conductor cable
should be run from the Keypad location to the local component location. As
many as four infrared emitters can be wired to a keypad by connecting in
SERIES as shown here:
To Main System
Series
Connections
Multiple Emitters should
connect in SERIES!
When connecting emmitters
directly to the keypad, addi-
tional resistance is needed,
usually between 100
Ω to
500
Ω depending on the
length of the run. Series
connections are recom-
mended!
There is no problem
connecting to the Main
system via the ALTER-
NATE MASTER [IN]
instead of the MASTER
[IN] as shown here.
Simply connect in paral-
lel with the Local TV
emitter cable.
Wiring requirements for emitters
are loose. Standard 2 conductor 16
gauge speaker wire is ideal for
long runs from the keypad to a
Local TV or device. Utilizing CAT 5
cable will also work well.
Emitter
For
DVD
+
-
+
+
+
-
-
-
Emitter For TV