13
lids are dried prior to replacing onto lower part of burner. While upper lid is soaking, clean lower part
of burner with a clean damp cloth soaked in a mild detergent.
Y
EARLY
C
HECKS
&
S
ERVICE
The appliance should be inspected and adjusted periodically by a qualified service person
as part of any kitchen maintenance program.
B&S recommends that this appliance is inspected at least annually by a authorized service
technician as follows:
Inspect the table inside-out for excessive build-up of any fats, oils and foodstuffs.
Inspect that the burners and other components (i.e. pilots, thermocouples, etc.) are in good condition
and functioning properly.
Inspect all gas connections for leaks and ensure all connections are tightened properly.
Ensure burner manifold pressure is in accordance with that specified on the data plate of the
appliance.
Inspect all gas connections for leaks and ensure all connections are tightened properly.
In case of difficulties contact B&S Commercial Kitchen Appliances Pty Ltd or their authorised
service agent.
S
ERVICING
I
NSTRUCTIONS
WARNING!
Servicing shall be carried out by authorised personnel
only
. Failure to do so will void the B&S
warranty and may result in damage to equipment or injury to personnel.
Before commencing any disassembly/assembly of gas controls, please ensure the gas supply is
turned off (isolated).
F
AILURE TO DO SO WILL VOID THE
B&S
W
ARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO
PERSONNEL
A
BNORMAL
O
PERATION
Any of the following are considered to be abnormal operation and may require servicing;
Incomplete ignition of burner/Burner failing to keep alight
Check burner is not blocked
Yellow tipping of the burner flame
Check aeration of burner
Pilot is not holding
Check connection of the thermocouple to the control is not loose.
Check if pilot flame is in contact with thermocouple
No pilot flame
Check main gas valve is in “ON” position.
Ensure pilot injector is not blocked
Gas valves which are difficult to turn
G
AINING
A
CCESS TO
B
OILING
T
OP
B
URNERS AND
P
ILOT
A
SSEMBLY
1.
To gain access to boiling top burners and pilot assembly, lift off trivets.
Note:
Use extreme care
when lifting off trivets as they may still be hot from appliance operation.
A
DJUSTING
B
OILING
T
OP
B
URNER
A
ERATION
2.
To adjust front row boiling top burners;