Bacharach Halogen Monitor Instruction

Other manuals for Halogen Monitor: Instruction

Summary of Halogen Monitor

  • Page 1

    Halogen monitor portable area gas monitor (pagm) with infrared sensor for halogen gases (refrigerants) instruction 3015-4584 operation & maintenance rev. 9 – february 2013 patent 6,590,690 product leadership • training • service • reliability.

  • Page 2

    Halogen monitor ii instruction 3015-4584 rev 9.

  • Page 3: Warranty

    Halogen monitor instruction 3015-4584 rev8 iii warranty bacharach, inc. Warrants to buyer that at the time of delivery this product will be free from defects in material and manufacture and will conform substantially to bacharach inc.'s applicable specifications. Bacharach's liability and buyer's re...

  • Page 4: Table Of Contents

    Table of contents halogen monitor iv instruction 3015-4584 rev 9 table of contents 1 introduction ....................................................................................................................................... 1 1.1 how to use this manual ........................................

  • Page 5

    Halogen monitor table of contents instruction 3015-4584 rev 9 v 2.18 importing saved data into a spreadsheet ................................................................................... 20 3 maintenance .............................................................................................

  • Page 7: 1 Introduction

    Halogen monitor introduction instruction 3015-4584 rev 9 1 1 introduction 1.1 how to use this manual this manual provides important information on how to operate and service bacharach’s refrigerant monitor. To assure operator safety and the proper use of the monitor, please read, understand, and fol...

  • Page 8: 1.5  Safety Precautions

    Introduction halogen monitor 2 instruction 3015-4584 rev 9 1.5 safety precautions hazardous area warning: this instrument has not been designed to be intrinsically safe for use in areas classified as hazardous locations. For your safety, do not use it in hazardous (classified) locations. Combustible...

  • Page 9: 1.7  Shipping Precaution

    Halogen monitor introduction instruction 3015-4584 rev 9 3 1.7 shipping precaution when shipping the instrument by air, deflate the purge-air bag to prevent it from bursting due to changes in air pressure. Deflate the bag by selecting the emtybag function as described on page 10. 1.8 features & capa...

  • Page 10: 1.10 Specifications

    Introduction halogen monitor 4 instruction 3015-4584 rev 9 1.10 specifications product type ......................... Portable refrigerant gas monitor gas library: cfc: r-11, r-12, r-113, r-114, r-502, hfp hfc: r-404a (hp62), r-407a, r-407c (ac9000), r-134a, r-410a (az20), r-507 (az50), r-508b (suva...

  • Page 11: 2 Operation

    Halogen monitor operation instruction 3015-4584 rev 9 5 2 operation 2.1 front panel display & controls 2.2 connecting gas-sample & exhaust lines 2.2.1 overview a single gas-sample line needs to be run from the hm unit to the area to be monitored. An optional purge- air line can also be installed to ...

  • Page 12: 2.3  General Operation

    Operation halogen monitor 6 instruction 3015-4584 rev 9 2.2.3 connecting the exhaust line the exhaust line carries the exhausted gas sample away from the monitor, and is required if the monitor is located in a confined, poorly ventilated area. The exhaust line can be up to 50 ft (15.2 m) in length. ...

  • Page 13

    Halogen monitor operation instruction 3015-4584 rev 9 7 the operator can reset the peak value to zero by pressing the enter button. The measurement cycle runs for 4 minutes. A log of up to 200 previous measurements can be viewed using the ppm log function (page 10). Purge indicates when the monitor ...

  • Page 14: 2.7  Standby Mode

    Operation halogen monitor 8 instruction 3015-4584 rev 9 tip: if no button is pressed within 60 seconds the monitor automatically continues with the current twa/twa. Note: during the time the monitor is off, the gas measurement is assumed to be zero and will be factored into the twa/twa calculation. ...

  • Page 15: 2.9   Display Screens

    Halogen monitor operation instruction 3015-4584 rev 9 9 2.8.2 using the battery the pagm is designed for a 16vdc input. Following the instructions for the particular battery in use, set the output voltage to 16v. Plug the battery into the instrument's battery input port and the instrument is ready f...

  • Page 16

    Operation halogen monitor 10 instruction 3015-4584 rev 9 during normal operation, the data display screen shows when the monitor is performing the following two functions: measure indicates that the monitor is actively measuring gas. In the screen shown above, 10 ppm of r-134a gas is currently being...

  • Page 17

    Halogen monitor operation instruction 3015-4584 rev 9 11 • twa alarm – audible alarm sounds when the twa or twa, whichever is selected by the 2ndunit function , exceeds the alarmlvl value. The audible alarm can be temporarily silenced by pressing the silence button. Ppm log – contains records of the...

  • Page 18: 2.10 Gas Alarm

    Operation halogen monitor 12 instruction 3015-4584 rev 9 gas – used to select one of any of the gas types available for monitoring. Factory default is r-134a. Note that the factory can program a custom gas type as specified on the sales order. Use the keypad to select the desired gas type, and then ...

  • Page 19: 2.11   System Faults

    Halogen monitor operation instruction 3015-4584 rev 9 13 the alarm log shows the type of alarm (leak, spill, or evac), plus the date and time it occurred. If clear is displayed, this indicates that an alarm was acknowledged at the date and time shown. Immediately after selecting the alarms function,...

  • Page 20

    Operation halogen monitor 14 instruction 3015-4584 rev 9 2.11.4 fault codes fault codes are additive . For example: a fault code of indicates that both a box temperature fault and a bench temperature fault have occurred. Code fault name description box temperature fault enclosure temperature is outs...

  • Page 21

    Halogen monitor operation instruction 3015-4584 rev 9 15 2.13 the diag function 2.13.1 overview the diag function displays sensor data and status information useful to a service technician for troubleshooting various fault conditions. Explanations of the data shown in these screens are given below. ...

  • Page 22: 2.15 The P-Chk Function

    Operation halogen monitor 16 instruction 3015-4584 rev 9 r134a calfactor 1.000 2.14 the calibration function if greater than standard accuracy is desired, the factory’s default calibration factor of 1.000 may be adjusted by performing the calibration procedure as described below, and then selecting ...

  • Page 23

    Halogen monitor operation instruction 3015-4584 rev 9 17 the keypad down button toggles the pump on and off. Pressing the enter button stores the current manifold pressure shown on the left to the ambient pressure shown on the right (must be done with the pump off). 2.15.3 screen display current man...

  • Page 24

    Operation halogen monitor 18 instruction 3015-4584 rev 9 2.17 downloading stored data to a personal computer using the monitor’s pc dump feature, the last 200 gas readings that were stored in memory can be downloaded to a personal computer in ascii text, comma-delimited format, which can then be imp...

  • Page 25

    Halogen monitor operation instruction 3015-4584 rev 9 19 • if hyperterminal has never been run in association with the monitor, then a new hyperterminal connection needs to be made as follows: a) click start ; click run . In the run box, type “hypertrm.Exe ” and click ok. The new connection dialog b...

  • Page 26

    Operation halogen monitor 20 instruction 3015-4584 rev 9 2.18 importing saved data into a spreadsheet a text file that was created as described in section 3.18 can be imported into spreadsheet programs that are capable of importing comma-delimited files. The following describes how to generate a spr...

  • Page 27: 3 Maintenance

    Halogen monitor maintenance instruction 3015-4584 rev 9 21 3 maintenance 3.1 disassembly when servicing the parts inside the hm unit, disassemble the monitor’s metal chassis as follows: items required: medium phillips head screwdriver procedure: 1. Remove monitor and its battery pack from the soft c...

  • Page 28: Replacement

    Maintenance halogen monitor 22 instruction 3015-4584 rev 9 3.2 internal particulate/hydrophobic filter replacement items required: replacement filter (p/n 0007-1654) medium phillips head screwdriver procedure: 1. Disassemble the monitor’s metal chassis per section 3.1. 2. See illustration below and ...

  • Page 29: 4 Parts And Service

    Halogen monitor maintenance instruction 3015-4584 rev 9 23 4 parts and service 4.1 replacement parts item description part number refrigerant monitor 3015-4484 replacement battery kit 3015-5739 soft carrying case with shoulder strap 3015-5700 bladder bag kit 3015-5325 stainless steel probe 3015-5326...

  • Page 30

    Headquarters: 621 hunt valley circle, new kensington, pa 15068 ph: 724-334-5000 • toll free: 800-736-4666 • fax: 724-334-5001 website: www.Mybacharach.Com • e-mail: help@mybacharach.Com printed in u.S.A. ® registered trademark of bacharach inc..