Bacharach HGM300 Product Catalog - page 34
B A C H A R A C H
®
| 1 . 8 0 0 . 7 3 6 . 4 6 6 6 | w w w. b a c h a r a c h - i n c . c o m
32
Tru Pointe
®
/ Top Gun H10Xpro
Bacharach’s newest refrigerant leak detector, the Tru Pointe
®
,
is designed specifically for technicians looking for a premium
quality leak detector at an affordable price.
The Tru Pointe
®
is designed to be instantly responsive to all
refrigerants. It is even accurate when used in environments
where high levels of refrigerant vapors are present. No manual
sensitivity adjustments are necessary during the inspection
process. Simply turn the unit on, and let it mark the spot!
F E AT U R E S
• Detects all CFC, HFC, and HCFC refrigerants using patented
heated diode sensor technology
• Instantaneous response time
• Innovative sensor replacement design
• Up to 20 hours continuous operation on 2 ‘D’ alkaline batteries
• Battery-powered with low battery indication
• Long-life, DC brushless fan
• High and low-sensitivity modes
• Automatic zero and background compensation
• Audible & visual leak indication
• Easy to use, one-handed operation
• No user calibration required
ORDERING INFORMATION
PART NO. DESCRIPTION
19-8106
Tru Pointe
®
, instruction manual, 2 ‘D’ Batteries and hard
carrying case
19-0501
Carrying Case
19-0559
Sensor
SPECIFICATIONS
Sensing Elements
Type:
Patented Heated Diode, Plug-in
Life Expectancy:
150 Hours or 1 year of normal use
Refrigerants Detected
All CFC, HCFC and HFC refrigerants, including
R-12, R-22, R-123, R-134a and blends R-404a,
R-408A, R-409A, and R-410A (i.e. any
refrigerant containing Chlorine, Fluorine or
Bromine gas)
Alarm Sensitivity of R-134a
0.5 oz / year (14g/year) per SAE J1627
(Hardest refrigeration
0.1 oz / year (3g/year) when probe is held
to detect)
over leak source for at least 5 seconds
Alarm Types
Variable-intensity audible and visual alarms
Power Source
Two ‘D’ Alkaline Batteries
Warm-Up Time
10 seconds
Response Time
Instantaneous
Battery Life*
15 hours minimum
Probe
14” (35.6cm) flexible
Size
2” W x 9.4” L x 2.5” H
(5 cm W x 23.8 cm L x 6.3 cm H)
Weight
1.16 lb (0.53kg) w/ batteries
Agency Approvals
UL Listed in accordance with SAE J1627, CE
Warranty
One year, including sensor
*As tested in low sensitivity mode using Duracell Ultra MX 1300 alkaline batteries
Leak Detection
F E AT U R E S
• Detects all CFC, HFC, and HCFC refrigerants
• Utilizes patented heated diode sensor technology
• Rechargeable Ni-Cad battery provides 3 to 4 hours of continuous
operation
• Includes 2 battery packs
• Contains 3 sensitivity modes
• Contains automatic and manual zero balance control
• Complies with SAE J1627
T O P G U N H 1 0 X P R O
H A N D - H E L D R E F R I G E R A N T L E A K D E T E C T O R
SPECIFICATIONS
Measures
All CFC, HFC, and HCFC Refrigerants
Sensing Element
Patented Heated Diode
Alarm Types
Variable Intensity Audible and Visual
Alarms
Probe Length
16" (40.6cm) - 8" (20.3cm) probe
optional
Power Source
Rechargeable 7.2V Ni-Cad Battery Pack
Warm-Up Time
10 Seconds
Operating Temperature
32 to 104°F (0 to 40°C)
Weight
1.2 lbs. (0.54 Kg)
Agency Approvals
UL file SA9717, SAE J1627, CE
Warranty
One year, including sensor
T R U P O I N T E ®
R E F R I G E R A N T L E A K D E T E C T O R
ORDERING INFORMATION
PART NO. DESCRIPTION
3015-0690 H10XPro with 110V battery charger, 16" probe, 2
rechargeable battery packs, instruction manual, and hard
carrying case
3015-1721 Sensor
3015-1476 BatteryPack
3015-1491 8" Probe