Bacharach HGM300 Product Catalog - page 37
B A C H A R A C H
®
| 1 . 8 0 0 . 7 3 6 . 4 6 6 6 | w w w. b a c h a r a c h - i n c . c o m
35
Leak Detection
The Informant
®
2 leak detector is
a modular system which is
totally upgradable. Order the
complete dual system or choose
dedicated refrigerant or
combustible gas units and
upgrade to the dual configuration
at any time in the future.
PART NO. DESCRIPTION
19-8038
Informant
®
2 Contractor Kit.
Instrument comes with refrigerant and combustible gas
sensors, color-coded sensor tips, instruction manual, 4 AA
batteries, filters and a hard carrying case.
19-8042
Dual Refrigerant/Combustible Informant
®
2 Detector Kit.
Instrument comes with refrigerant and combustible gas
sensors, color-coded sensor tips, instruction manual, 4 AA
batteries, 5 filters and a custom soft carrying case.
19-8045
Dual Deluxe Refrigerant/Combustible Informant
®
2 Detector Kit.
Instrument comes with refrigerant and combustible gas
sensors, color-coded probe tips, protective rubber boot,
flashlight, instruction manual, 6 AA batteries and 5 filters, all
packaged in a hard carrying case.
19-8040
Refrigerant Only Informant
®
2 Detector Kit.
Instrument comes with refrigerant sensor, color-coded probe
tip, instruction manual, 4 AA batteries, 5 filters and a custom
carrying case.
19-8037
Deluxe Upgrade Kit.
Includes protective rubber boot, flashlight, 2AA batteries and
a hard carrying case.
19-8047
Combustible Gas Upgrade Kit.
To upgrade a refrigerant only Informant
®
2 to a dual sensing
instrument. Includes combustible gas sensor, color-coded
probe tip and 5 filters
19-0499
Replacement combustible sensor
19-0510
Replacement refrigerant sensor
19-0509
Replacement filters (5-pack)
ORDERING INFORMATION
Sensing Elements:
Refrigerant
Heated Diode - U.S. Patent No. 5,932,176
Combustible
Patented semiconductor type. Five year typical life.
Plug-in replacement
Refrigerants Detected:
All CFC, HCFC and HFC refrigerants including: R-12, R-22,
R-123. R-134a and blends R-404A, R-408A, R-409A and
R-410A (i.e., any refrigerant containing Chlorine, Flourine or
Bromine gas)
Combustible Gases Detected: All combustible gases and vapors
Alarm Sensitivity:
Refrigerant
Less than 0.25 oz/yr of R-134a (hardest to detect refrigerant)
Combustible
Minimum 50ppm (Methane)
Alarm Types:
Audible, dual visual LED’s and flashing probe tip
Power Source:
Four (4) AA disposable alkaline batteries included
Warm-up Time:
10 seconds
Response Time:
Refrigerant
Instantaneous
Combustible
Instantaneous
Battery Life:
4-5 hours, under typical intermittent operation
Probe:
20” (50.8 cm) maximum length, fully extended; 3” (7.62 cm)
if wrapped around instrument. Includes LED indicator
Size:
1.75”W x 9.62”L x 2.25”H (4.45 cm x 24.43 cm x 5.72 cm)
Weight:
0.86 lbs. (0.39 kg) with batteries
Agency Approvals:
Refrigerant
UL listed in accordance with SAE J1627
Combustible
MET Lab certified to UL 913, intrinsically safe for use in
Class1, Division 1, Group D hazardous areas
Warranty:
One year, including sensors
SPECIFICATIONS