  • Page 1

    ® badger meter europa gmbh modmag ® m1000 hart ® protocol installation and operation manual april 2017 mid_m1000_ba_hart_02_1704.

  • Page 2

    Contents page mid_m1000_ba_hart_02_1704 1. Basic safety recommendations ..................................................................................... 5 2. Dynamic variables .......................................................................................................... 5 volumetric...

  • Page 3

    Contents page mid_m1000_ba_hart_02_1704 command 134 read compile date ........................................................................36 command 135 read otp boot checksum ............................................................37 command 136 read flash os checksum .........................

  • Page 4

    Contents page mid_m1000_ba_hart_02_1704 command 210 read digital output operation .......................................................66 command 211 write digital output operation........................................................67 command 212 read full scale frequency ........................

  • Page 5

    Basic safety recommendations / dynamic variables page 5/83 mid_m1000_ba_hart_02_1704 1. Basic safety recommendations please see “basic safety recommendations” in installation and operation manual modmag ® m1000. 2. Dynamic variables primary variable volumetric flow rate secondary variable t1+ tertia...

  • Page 6

    Dynamic variables / device variables page 6/83 mid_m1000_ba_hart_02_1704 volume unit code 40 gallons 41 liters 42 imperial gallons 43 cubic meters 46 barrels 112 cubic feet 236 hectoliters 240 mega gallons 241 acre-feet 3. Device variables code classification units value status response code 0 volum...

  • Page 7

    Dynamic variables / device variables page 7/83 mid_m1000_ba_hart_02_1704 status α flow meter status device variable status flow simulation active manual fixed; not limited bad bad; not limited good good; not limited status β flow meter status device variable status bad bad; not limited good good; no...

  • Page 8

    Field device status page 8/83 mid_m1000_ba_hart_02_1704 4. Field device status bit status indication meaning 7 field device malfunction some fault occurred, except pulse output overload 6 configuration changed set whenever a configuration change is made by any host, or through a local operator inter...

  • Page 9

    Universal commands page 9/83 mid_m1000_ba_hart_02_1704 5. Universal commands command 0 read transmitter unique identifier request data bytes byte description none response data bytes byte description #0 device type code for expansion 254 #1 manufacturer identification mode 189 = badger meter #2 manu...

  • Page 10

    Universal commands page 10/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r a ddr es s c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 06 80 00 18 00 42 fe bd 03 05 07 01 0e 08 00 0a e1 39 05 0d 00 01 00 00 bd 00 bd 01 43 command 1 read primary variabl...

  • Page 11

    Universal commands page 11/83 mid_m1000_ba_hart_02_1704 request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 02 00 ec response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec...

  • Page 12

    Universal commands page 12/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 8 6 bd 03 0a e1 39 0 3 1a 00 42 41 a0 00 00 18 40 a0 e0 91 29 49 4c ef 7c 29 42 7d f6 14 29 49 4c ...

  • Page 13

    Universal commands page 13/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 03 1a 00 42 41 a0 00 00 18 40 a0 e0 91 29 49 4c ef 7c 29 42 7d f6 14 29 49 4c eb...

  • Page 14

    Universal commands page 14/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 06 04 00 48 00 00 a0 data: polling address = 0 loop current mode = 0 (signaling ...

  • Page 15

    Universal commands page 15/83 mid_m1000_ba_hart_02_1704 command 7 read loop configuration request data bytes byte description none response data bytes byte description #0 polling address 0 (0..63) #1 loop current mode 0=disabled; 1=enabled response codes code description 0 no command specific error ...

  • Page 16

    Universal commands page 16/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 08 00 e6 response example: preamble s ta rt d el im ite r address long fr...

  • Page 17

    Universal commands page 17/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error 2 invalid selection 5 too few data bytes received 14 device variables returned for device variables 30 command response truncated request example: preamble start delimiter address comm...

  • Page 18

    Universal commands page 18/83 mid_m1000_ba_hart_02_1704 command 11 read unique identifier associated with tag request data bytes byte description #0..#5 tag (packed ascii) response data bytes same as command 0 read unique identifier response codes code description 0 no command specific error request...

  • Page 19

    Universal commands page 19/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 0c 1a 00 42 08 11 07 15 28 0d 15 41 52 80 93 83 b2 03 71 c3 0c 20 82 08 20 82 08...

  • Page 20

    Universal commands page 20/83 mid_m1000_ba_hart_02_1704 command 14 read pv sensor information request data bytes byte description none response data bytes byte description #0..#2 transducer serial number #3 transducer limits and minimum span units code volumetric flow unit codes #4..#7 upper transdu...

  • Page 21

    Universal commands page 21/83 mid_m1000_ba_hart_02_1704 command 15 read pv output sensor information request data bytes byte description none response data bytes byte description #0 pv alarm selection code 0 .. High 1 … low 251 … none 252 … unknown #1 pv transfer function code 0 = linear #2 pv upper...

  • Page 22

    Universal commands page 22/83 mid_m1000_ba_hart_02_1704 command 16 read assembly number request data bytes byte description none response data bytes byte description #0..#2 final assembly number response codes code description 0 no command specific error request example: preamble start delimiter add...

  • Page 23

    Universal commands page 23/83 mid_m1000_ba_hart_02_1704 request example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t data c hec ks um ff ff ff ff ff 82 bd 03 0a e1 39 11 18 08 11 07 15 28 0d 15 41 52 80 93 83 b2 03 71 c3 0c 20 82 08 20 82 08 2d 7d response e...

  • Page 24

    Universal commands page 24/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 12 17 00 42 37 1c 30 c2 08 20 82 08 20 82 08 20 82 08 20 82 08 20 1b 08 72 3d da...

  • Page 25

    Universal commands page 25/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 13 05 00 42 2c 1b 0a 83 data: final assembly number: 2c 1b 0a command 20 read lo...

  • Page 26

    Universal commands page 26/83 mid_m1000_ba_hart_02_1704 command 21 read unique identifier associated with long tag request data bytes byte description #0..#31 long tag (latin-1) response data bytes same as command 0 read unique identifier response codes code description 0 no command specific error r...

  • Page 27

    Universal commands page 27/83 mid_m1000_ba_hart_02_1704 request example: preamble s ta rt d el im ite r address c om m and by te c oun t data c hec ks um ff ff ff ff ff 82 bd 03 0a e1 39 16 20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 d8 response...

  • Page 28

    Universal commands page 28/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 26 04 00 02 00 02 c8 command 48 read additional device status request data bytes...

  • Page 29

    Universal commands page 29/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error 5 too few data bytes 14 dynamic variables returned for device variables request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 3...

  • Page 30

    Additional features page 30/83 mid_m1000_ba_hart_02_1704 6. Additional features command 40 enter/exit fixed current mode request data bytes byte description #0..#3 primary variable fixed current level (units of ma) , ieee754 response data bytes byte description #0..#3 actual primary variable current...

  • Page 31

    Additional features page 31/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 28 06 00 00 41 61 8b fc 93 data: 14.09667 ma actual command 42 perform device r...

  • Page 32

    Additional features page 32/83 mid_m1000_ba_hart_02_1704 command 44 write primary variable units request data bytes byte description #0 primary variable units code volumetric flow unit codes response data bytes byte description #0 primary variable units code volumetric flow unit codes response codes...

  • Page 33

    Additional features page 33/83 mid_m1000_ba_hart_02_1704 request example: preamble start delimiter address command byte count data checksum ff ff ff ff ff 82 bd 03 0a e1 39 3b 01 05 d1 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s d...

  • Page 34

    Device specific commands page 34/83 mid_m1000_ba_hart_02_1704 7. Device specific commands command 130 read product code request data bytes byte description none response data bytes byte description #0..#1 product code 4 .. M1000r response codes code description 0 no command specific error request ex...

  • Page 35

    Device specific commands page 35/83 mid_m1000_ba_hart_02_1704 request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 83 00 6d response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data...

  • Page 36

    Device specific commands page 36/83 mid_m1000_ba_hart_02_1704 command 133 read application version request data bytes byte description none response data bytes byte description #0..#19 application version, latin-1 response codes code description 0 no command specific error request example: preamble ...

  • Page 37

    Device specific commands page 37/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 86 05 00 00 10 0a 72 01 day = 16 month = 10 (october) year =2014 command 1...

  • Page 38

    Device specific commands page 38/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 88 00 66 response example: preamble s ta rt d el im ite r address l...

  • Page 39

    Device specific commands page 39/83 mid_m1000_ba_hart_02_1704 command 150 read detector diameter request data bytes byte description none response data bytes byte description #0..#1 detector diameter 1 dn6 2 dn8 3 dn10 4 dn15 5 dn20 6 dn25 7 dn32 8 dn40 9 dn50 10 dn65 11 dn80 12 dn100 13 dn125 14 dn...

  • Page 40

    Device specific commands page 40/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 96 00 78 response example: preamble s ta rt d el im ite r address l...

  • Page 41

    Device specific commands page 41/83 mid_m1000_ba_hart_02_1704 command 156 read detector offset request data bytes byte description none response data bytes byte description #0..#4 detector offset [m/s], ieee754 adjusted by manufacturer during wet calibration response codes code description 0 no comm...

  • Page 42

    Device specific commands page 42/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 9e 06 00 42 4b 81 64 42 dc amplifier factor = 16959620.0 command 160 read ...

  • Page 43

    Device specific commands page 43/83 mid_m1000_ba_hart_02_1704 command 162 read power line frequency request data bytes byte description none response data bytes byte description #0..#1 power line frequency 0 50hz 1 60hz response codes code description 0 no command specific error request example: pre...

  • Page 44

    Device specific commands page 44/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 a3 04 00 42 00 01 0e power line frequency = 60hz command 164 read excitati...

  • Page 45

    Device specific commands page 45/83 mid_m1000_ba_hart_02_1704 command 165 write excitation frequency request data bytes byte description #0..#1 excitation frequency see excitation frequency enumeration response data bytes byte description #0..#1 excitation frequency see excitation frequency enumerat...

  • Page 46

    Device specific commands page 46/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 a6 06 00 42 3f 80 00 00 b7 scale factor = 1.0 command 167 write scale fact...

  • Page 47

    Device specific commands page 47/83 mid_m1000_ba_hart_02_1704 command 172 read polarization voltage request data bytes byte description none response data bytes byte description #0..#3 polarization voltage [v], ieee754 for debugging purposes response codes code description 0 no command specific erro...

  • Page 48

    Device specific commands page 48/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 ad 06 00 42 43 93 43 1d 8d full scale flow = 294.5243 command 174 write fu...

  • Page 49

    Device specific commands page 49/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 af 00 41 response example: preamble s ta rt d el im ite r address l...

  • Page 50

    Device specific commands page 50/83 mid_m1000_ba_hart_02_1704 command 177 read volume unit request data bytes byte description none response data bytes byte description #0 volumetric volume unit volume unit codes response codes code description 0 no command specific error request example: preamble s...

  • Page 51

    Device specific commands page 51/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 b2 03 00 42 29 30 volume unit = liters command 181 read full scale velocit...

  • Page 52

    Device specific commands page 52/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error 2 invalid selection 5 too few data bytes received 16 access restricted request example: preamble start delimiter address command byte count data checksum ff ff ff ff ff 82 bd 03 ...

  • Page 53

    Device specific commands page 53/83 mid_m1000_ba_hart_02_1704 command 184 write low flow cut off request data bytes byte description #0…#3 low flow cut off [%], ieee754 percent of full scale flow (0.0 … 10.0) response data bytes byte description #0…#3 low flow cut off [%], ieee754 percent of full sc...

  • Page 54

    Device specific commands page 54/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 b9 03 00 00 00 50 flow direction = unidirectional command 186 write flow d...

  • Page 55

    Device specific commands page 55/83 mid_m1000_ba_hart_02_1704 response data bytes byte description #0…#3 coil settling time [s], ieee754 for debugging purposes response codes code description 0 no command specific error request example: preamble start delimiter address command byte count checksum ff...

  • Page 56

    Device specific commands page 56/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 be 03 00 00 00 57 digital input operation = none command 191 write flow di...

  • Page 57

    Device specific commands page 57/83 mid_m1000_ba_hart_02_1704 response example : preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 bf 03 00 40 01 17 digital input operation = totalizer reset command 192 r...

  • Page 58

    Device specific commands page 58/83 mid_m1000_ba_hart_02_1704 command 197 write alarm mode request data bytes byte description #0 alarm mode 0 .. High 1 … low 251 … none response data bytes byte description #0 alarm mode 0 .. High 1 … low 251 … none 252 … unknown response codes code description 0 no...

  • Page 59

    Device specific commands page 59/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error request example: preamble start delimiter address command byte count checksum ff ff ff ff ff 82 bd 03 0a e1 39 c8 00 26 response example: preamble s ta rt d el im ite r address l...

  • Page 60

    Device specific commands page 60/83 mid_m1000_ba_hart_02_1704 command 202 read pulse width request data bytes byte description none response data bytes byte description #0…#1 pulse width [ms] 5 … 2000 ms 0 ms (means 50% duty cycle) response codes code description 0 no command specific error request ...

  • Page 61

    Device specific commands page 61/83 mid_m1000_ba_hart_02_1704 request example: preamble start delimiter address command byte count data checksum ff ff ff ff ff 82 bd 03 0a e1 39 cb 02 00 32 15 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s t...

  • Page 62

    Device specific commands page 62/83 mid_m1000_ba_hart_02_1704 command 205 write flow alarm min if actual flow is outside the limit (lower than min or higher than max) corresponding output is activated. Request data bytes byte description #0 digital output number 1 … out1 2 … out2 #1 flow alarm min [...

  • Page 63

    Device specific commands page 63/83 mid_m1000_ba_hart_02_1704 command 206 read flow alarm max if actual flow is outside the limit (lower than min or higher than max) corresponding output is activated. Request data bytes byte description #0 digital output number 1 … out1 2 … out2 response data bytes ...

  • Page 64

    Device specific commands page 64/83 mid_m1000_ba_hart_02_1704 command 207 write flow alarm max if actual flow is outside the limit (lower than min or higher than max) corresponding output is activated. Request data bytes byte description #0 digital output number 1 … out1 2 … out2 #1 flow alarm max [...

  • Page 65

    Device specific commands page 65/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error 2 invalid selection 5 too few data bytes received request example: preamble start delimiter address command byte count data checksum ff ff ff ff ff 82 bd 03 0a e1 39 d0 01 01 3e ...

  • Page 66

    Device specific commands page 66/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 d1 04 00 40 01 01 7f digital output number = out1 digital output mode = no...

  • Page 67

    Device specific commands page 67/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 d2 04 00 00 01 01 3c digital output number = out1 digital output operation...

  • Page 68

    Device specific commands page 68/83 mid_m1000_ba_hart_02_1704 command 212 read full scale frequency request data bytes byte description none response data bytes byte description #0…#3 full scale frequency [hz], ieee754 response codes code description 0 no command specific error request example: prea...

  • Page 69

    Device specific commands page 69/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 d5 06 00 40 42 c8 00 00 f3 full scale frequency = 100.0 hz command 214 rea...

  • Page 70

    Device specific commands page 70/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error 2 invalid selection 5 too few data bytes received 16 access restricted request example: preamble start delimiter address command byte count data checksum ff ff ff ff ff 82 bd 03 ...

  • Page 71

    Device specific commands page 71/83 mid_m1000_ba_hart_02_1704 command 217 write moving average request data bytes byte description #0..#1 moving average filter 1 ... 200 length of filter response data bytes byte description #0..#1 moving average filter 1 ... 200 length of filter response codes code ...

  • Page 72

    Device specific commands page 72/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 e5 03 00 00 00 0c menu language code = english command 230 write menu lang...

  • Page 73

    Device specific commands page 73/83 mid_m1000_ba_hart_02_1704 command 231 read empty pipe mode request data bytes byte description none response data bytes byte description #0 empty pipe mode 0 … empty pipe detection off 1 … empty pipe detection on response codes code description 0 no command specif...

  • Page 74

    Device specific commands page 74/83 mid_m1000_ba_hart_02_1704 response example: preamble s ta rt d el im ite r address long frame from slave c om m and b yt e coun t s ta tu s data c hec ks um ff ff ff ff ff 86 bd 03 0a e1 39 e8 03 00 40 00 41 empty pipe mode = empty pipe detection off command 233 r...

  • Page 75

    Device specific commands page 75/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error 2 invalid selection 5 too few data bytes received 16 access restricted request example: preamble start delimiter address command byte count data checksum ff ff ff ff ff 82 bd 03 ...

  • Page 76

    Device specific commands page 76/83 mid_m1000_ba_hart_02_1704 command 240 read flow simulation request data bytes byte description none response data bytes byte description #0 flow simulation [%] -128 … off + 0 … 0% +10 … +10% +20 … +20% +30 … +30% +40 … +40% +50 … +50% +60 … +60% +70 … +70% +80 … +...

  • Page 77

    Device specific commands page 77/83 mid_m1000_ba_hart_02_1704 command 241 write flow simulation request data bytes byte description #0 flow simulation [%], not stored to non-volatile memory -128 … off + 0 … 0% +10 … +10% +20 … +20% +30 … +30% +40 … +40% +50 … +50% +60 … +60% +70 … +70% +80 … +80% +9...

  • Page 78

    Device specific commands page 78/83 mid_m1000_ba_hart_02_1704 response data bytes byte description #0 flow simulation [%] -128 … off + 0 … 0% +10 … +10% +20 … +20% +30 … +30% +40 … +40% +50 … +50% +60 … +60% +70 … +70% +80 … +80% +90 … +90% +100 … +100% -10 … -10% -20 … -20% -30 … -30% -40 … -40% -5...

  • Page 79

    Device specific commands page 79/83 mid_m1000_ba_hart_02_1704 command 242 remote login request data bytes byte description #0..#3 login ask manufacturer for details. R esponse data bytes byte description #0 rights 0 ... Rights_unknown, 1 ... Rights_user, 2 ... Rights_service, 3 ... Rights_admin, 4 ....

  • Page 80

    Device specific commands page 80/83 mid_m1000_ba_hart_02_1704 response codes code description 0 no command specific error 2 invalid selection 5 too few data bytes received 16 access restricted request example: preamble start delimiter address command byte count data checksum ff ff ff ff ff 82 bd 03 ...

  • Page 81

    Device specific commands page 81/83 mid_m1000_ba_hart_02_1704 command 247 read random generates random number necessary for login calculation. Request data bytes byte description response data bytes byte description #0 rights 0 ... Rights_unknown, 1 ... Rights_user, 2 ... Rights_service, 3 ... Right...

  • Page 82

    ‘rights summary page 82/83 mid_m1000_ba_hart_02_1704 8. Rights – summary command_163_write_power_line_frequency rights_user command_165_write_excitation_frequency rights_service command_167_write_scale_factor rights_service command_174_write_full_scale_flow rights_factory command_176_write_flow_unit...

  • Page 83

    Return of goods for repair/hamless declarat page 83/83 mid_m1000_ba_hart_02_1704 9. Return of goods for repair/harmless declaration please refer to our claims return form/harmlessness declaration under www.Badgermeter.De/service/return of goods..

  • Page 84

    Mid_m1000_ba_hart_02_1704.

  • Page 85: Hotline

    Hotline phone +49-7025-9208-0 or -30 fax +49-7025-9208-15 ® badger meter europa gmbh subsidiary of badger meter, inc., usa nürtinger strasse 76 72639 neuffen (germany) e-mail: badger@badgermeter.De www.Badgermeter.De.