Baldor MotiFlex e100 Installation Manual - 3.1 Introduction
www.baldormotion.com
Basic Installation 3-1
MN1943
3.1 Introduction
You should read all the sections in Basic Installation to ensure safe installation.
This section describes the mechanical and electrical installation of the MotiFlex e100 in the
following stages:
H
Location considerations.
H
Mounting the MotiFlex e100.
H
Connecting the AC power supply.
H
Connecting the optional 24 VDC control circuit backup supply.
H
Connecting the motor.
H
Installing a regeneration resistor (Dynamic Brake).
3.1.1 Power sources
A 230 - 480 VAC 3-phase power source (IEC1010 over-voltage category III or less) in the
installation area is required. An AC power filter is required to comply with the CE directive for
which the MotiFlex e100 was tested (see section 3.4.10).
The optional 24 VDC control circuit backup supply must be a regulated power supply with a
continuous current supply capability of up to 1.5 A, dependent on the number of option cards
fitted. See section 3.6 for details.
3.1.2 Hardware requirements
The components you will need to complete the basic installation are:
H
AC power supply filter (for CE compliance).
H
The motor that will be connected to the MotiFlex e100.
H
A motor power cable.
H
An incremental encoder feedback cable, SSI cable, or BiSS / EnDat / SinCos cable.
A separate Hall cable might also be required for linear motors.
H
A USB cable.
H
(Optional) 24 VDC control circuit backup power supply.
H
(Optional) A regeneration resistor (Dynamic Brake) might be required, depending on the
application. Without the regeneration resistor, the drive may produce an overvoltage fault. All
MotiFlex e100 models have overvoltage sensing circuitry. Regeneration resistors may be
purchased separately - see section 3.8 and appendix A.