Baldor MotiFlex e100 Installation Manual - 3.3 Connector Locations
www.baldormotion.com
Basic Installation 3-11
MN1943
3.3 Connector locations
3.3.1 Front panel connectors
13 Status+
14 DGND
15 DOUT1+
16 DIN2+
17 DGND
18 DIN1+
19 DIN0+
20 DGND
21 Drive enable+
22 Shield
23 AGND
24 AIN0+
1 (NC)
2 Data-
3 Data+
4 GND
X3 Input / Output
USB
1 Status-
2 DGND
3 DOUT1-
4 DIN2-
5 DGND
6 DIN1-
7 DIN0-
8 DGND
9 Drive enable-
10 Shield
11 AGND
12 AIN0-
Node ID
These switches set the MotiFlex e100’s
node ID for Ethernet POWERLINK, and the
final value of the IP address when using
TCP/IP. See sections 5.8.1 and 6.2.4.
LEDs
The STATUS, CAN and ETHERNET
LEDs are described in section 7.2.1.
Tightening torque for terminal block connections (X2 & X3) is 0.5-0.6 N·m (4.4-5.3 lb-in).
Tightening torque for option slot 1/2 retaining screws is 0.7 N·m (6.2 lb-in).
Maximum wire / ferrule size (X2): 2.5 mm
2
(14 AWG).
Maximum wire size (X3): 0.5 mm
2
(20 AWG). Connector X3 is designed to accept bare wires only; do not use
bootlace ferrules.
(NC)
= Not Connected. Do not make a connection to this pin.
18 V out / 24 V in
0 V
X2 18 VDC output / 24 VDC backup input
Option slot 1 retaining screw.
Option slot 2 retaining screw.
To remove the top cover, push on the center of the bottom edge, then pull
the top edge forwards. To refit, locate the cover over its intended position
and then push on until it snaps into place.
To remove the bottom cover, push on the oval indentation and slide the
cover downwards. To refit, insert the two tabs, protruding from the cover’s
top edge, into the main body. Push on the Baldor label to snap into place.
1 TXA
2 TXB
3 GND
4 +7V out
5 (NC)
6 (NC)
X6 RS485 (2-wire)