Banner DF-G1-NR-2M Quick start manual

Manual is about: DF-G1 Expert Dual Display Fiber Optic Light Receiver

Summary of DF-G1-NR-2M

  • Page 1

    Quick start guide advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies for complete technical information about this product, including dimensions, accessories, and specifications, see www.Bannerengineering.Com and search 176768. Warning: not to be used fo...

  • Page 2

    Installation instructions mounting instructions mount on a din rail 1. Hook the din rail clip on the bottom of the df-g1 over the edge of the din rail (1). 2. Push the df-g1 up on the din rail (1). 3. Pivot the df-g1 onto the din rail, pressing until it snaps into place (2). Mount to the accessory b...

  • Page 3

    Wiring diagrams npn models pnp models key 1 = brown 2 = white 3 = blue 4 = black euro 2 3 4 1 pico 4 3 1 2 for cable options, see http:// www.Bannerengineering.Com note: open lead wires must be connected to a terminal block. Top panel interface opening the dust cover provides access to the top panel...

  • Page 4

    Remote input for more information about how to perform teach/set methods and to program the sensor remotely, see www.Bannerengineering.Com and search 176768. Run mode run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/set/- rocker button is disabled ...

  • Page 5

    Program mode program (prg) mode allows the following settings to be programmed in the df-g1: factory default settings: setting factory default threshold 5000 teach selection two-point teach response speed 50 ms offset percent 50% off delay 0 (disabled) off one-shot 0 (disabled) on delay 0 (disabled)...

  • Page 6

    Adjust mode sliding the run/prg/adj mode switch to the adj position allows the user to perform expert teach/set methods and manual adjustment of the threshold(s). Two-point teach • establishes a single switching threshold • threshold can be adjusted using "+" and "-" rocker button (manual adjust) tw...

  • Page 7

    Method action result set button a. Present the first condition. B. Click the set rocker button display: flashes "2pt tch" then holds on "1234 2nd" remote input a. Present the first condition. B. Single-pulse the remote input. T 3. Teach the second condition. Method action result set button a. Presen...

  • Page 8

    Sensor positions threshold midway between taught conditions darkest (no signal) most light (saturated signal) output off output on darkest taught condition lightest taught condition position adjusted by manual adjust figure 3. Dynamic teach (light operate shown) the output on and off conditions can ...

  • Page 9

    4. Exit dynamic teach. Method action result set button click the set rocker button teach accepted displays alternate "pass" with % minimum difference7, sensor returns to adjust mode teach not accepted displays alternate "fail" with % minimum difference7, sensor returns to adjust mode remote input si...

  • Page 10

    Sensor positions window thresholds a programmable % offset from the presented condition darkest (no signal) most light (saturated signal) condition presented sensing window center adjusted by manual adjust output off output off output on figure 4. Window set (light operate shown) output on and off c...

  • Page 11

    Method action result set button • present sensing condition • click the set rocker button threshold condition accepted displays read "wind set" then alternate "pass" with % offset10; sensor returns to adjust mode threshold condition not accepted displays read "wind set" then alternate "fail" with mi...

  • Page 12

    Note: for window set and light set, the maximum offset threshold percent is 90%. Threshold position adjusted by manual adjust sensor positions threshold a programmable % offset below the presented condition darkest (no signal) most light (saturated signal) output off output on condition presented fi...

  • Page 13

    Method action result set button • present sensing condition • click the set rocker button threshold condition accepted displays read "lt set" then alternate "pass" with % offset13; sensor returns to adjust mode threshold condition not accepted displays read "lt set" then alternate "fail" with minimu...

  • Page 14

    Sensor positions threshold a programmable % offset above the presented condition threshold position adjusted by manual adjust darkest (no signal) most light (saturated signal) output off output on condition presented figure 7. Dark set (light operate shown) dark set and manual adjust moves switching...

  • Page 15

    Method action result set button • present sensing condition • click the set rocker button threshold condition accepted displays read "dr set" then alternate "pass" with % offset16; sensor returns to adjust mode threshold condition not accepted displays read "dr set" then alternate "fail" with minimu...

  • Page 16

    ◦ green display shows the switching threshold value ◦ 2 seconds after adjustment, the green display will flash 3 times to confirm • slide mode switch to run to complete operation follow these steps to perform a calibration set: note: teach selection must be programmed to cal set (see program mode on...

  • Page 17

    Value pass/fail description 0 to 99% fail the difference of the taught conditions does not meet the required minimum 100 to 300% pass the difference of the taught conditions just meets/exceeds the required minimum, minor sensing variables may affect sensing reliability 300 to 600% pass the differenc...

  • Page 18

    This limited warranty is exclusive and in lieu of all other warranties whether express or implied (including, without limitation, any warranty of merchantability or fitness for a particular purpose), and whether arising under course of performance, course of dealing or trade usage. This warranty is ...