Banner DF-G1-NR-2M Quick start manual - page 9
4. Exit Dynamic TEACH.
Method
Action
Result
SET Button
Click the SET rocker button
TEACH Accepted
Displays alternate "PASS" with %
Minimum Difference7, Sensor returns
to Adjust mode
TEACH Not Accepted
Displays alternate "FAIL" with %
Minimum Difference7, Sensor returns
to Adjust mode
Remote Input
Single-pulse remote input
T
5. Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
Window SET
•
Sets window thresholds that extend a programmable % offset above and below the presented condition
•
All other conditions (lighter or darker) cause the output to change state
•
Sensing window center can be adjusted using "+\" and "-" rocker button (Manual Adjust)
•
Recommended for applications where a product may not always appear in the same place, or when other signals
may appear
•
See Program Mode in the user's manual for programming the Offset Percent setting (to increase/decrease the
window size)
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and
below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside
the window, and the Output OFF conditions outside the window (see
Figure 4
on page 10).
NOTE: For Window SET and Light SET, the maximum offset threshold percent is 90%.
7 See
Troubleshooting
on page 16 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH
method.
DF-G1 Expert
™
Dual Display Fiber Optic Light Receiver
P/N 172436 Rev. C
www.bannerengineering.com - tel: 763-544-3164
9