BullFrog 2000 Owner's Manual - page 14
Page 14
Bullfrog Spas Owner’s Manual
Standard and Economy Mode
The Standard Mode is the default operation mode for
the spa. When in Standard mode, the spa maintains
the desired temperature at all times. In Economy
mode, the spa only heats water during filter cycles
and has a fixed temperature setting of 100°F. To
activate the Economy Mode, change the temperature
setting on the Master Control Pad down to 80°F by
pressing the “Temp Set” button. Press the button
again and your spa will enter into the Economy Mode.
Standby Mode
(Use when removing JetPaks or cleaning the filter)
Press the “Temp Set” temperature button and then the
"Light" button. The display will show "Sb" and all
functions will be disabled except for freeze control.
Press any button to reset the system.
Preset Filter Cycles: Your spa will automatically filter
itself twice each day. The first filter cycle will begin
one minute after the spa is energized. The second
filter cycle will begin twelve hours after the start of
the first filter cycle. Filtration duration is
programmable at the Master Control Pad. Press the
"Temp Set" button, then the "Jets" button, and "F4" will
be displayed on the panel. F4 is the default filter time
and indicates a 4 hour cycle. Continue pressing the
“Temp Set” button to cycle through the rest of the
filter time options; "F2" = 2 hours, "F4" = 4 hours, and
"F6" = 6 hours. Press the "Jets/Jets 1" button to exit
filter programming. During filtration, the low-speed
pump and ozone sterilizer (if installed) will run.
Ozone Sterilizer (optional): For safety purposes, your
Ozone Sterilizer is disabled for a 30 minute period
whenever a “Jets” button is pressed.
SAFETY/FEATURE MESSAGES:
Overheat Protection (Spa is Deactivated.)
DO NOT ENTER THE WATER. If a malfunction occurs
and the spa water has reached 112°F, the display will
flash “OH” (meaning over-heat) and the system will
completely shut down. Remove the cover to cool the
water. Overheating may also occur if the filter
duration is set too long. At 110°F, the spa should
reset itself. If the high-limit sensor detects 118°F at
the heater, the spa will shut down. When the heater
cools to 110°F, press any button to reset the spa. If
the spa will not reset, then shut off power to the spa
and contact your authorized Bullfrog Spa Dealer.
Flow Switch Detection
If the panel display is flashing “FL” (meaning flow)
alternately with Temperature, one of the following
may have occurred:
1- The filter may be plugged. Remove the filter and