  • Page 1

    1. Set-up the laminator should be installed on a table where you have access to the front and rear side of the unit. Special care must be taken to avoid any uv light emission to the laminate. Even white light from normal room illumination will expose the laminate. We recom- mend that you install yel...

  • Page 2

    The thermostat has a soft heat-up functionthat prevents over-temperature on the lamination rollers. After each initial start the lower display will show increasing temperature values until the set value is reached. Temperature setting proposals are about105 °c for photoresistand 115 °c for solder ma...

  • Page 3

    Ved before the laminate goes on the board. This separation foil will wind up on the take-up rollers. Pull the laminate off the lower coil for about 30 cm. Apply a piece of adhesive tape to the upper and lower end of the laminate compound and pull these ‘‘handles’’ to separate the thin and soft inter...

  • Page 4

    This snaps onto the pins as well. Adjust the lateral guide bar of the inlet table so that the left pcb edge matches the left edge of the laminate film. It is assumed that at the end of each job you leave a piece of cardboard between the lamination rollers. This serves to keep the lamination rollers ...

  • Page 5

    Transport / lamination rollers transport / laminierwalze guide roller umlenkrolle take-up roller aufwickelrolle laminate coil laminatrolle take-up roller aufwickelrolle laminate coil laminatrolle bungard elektronik ·rilke str. 1 · d-51570 windeck tel 02292 5036 · fax 6175 · info@bungard.De rlm 419p ...

  • Page 8

    Eg-konformitätserklärung declaration of conformity déclaration de conformitée wir (name des anbieters) we (suppliers name) nous (nom du fournisseur) bungard elektronik anschrift rilke straße 1 address d-51570windeck adresse erklären in alleiniger verantwortung, daß die produkte declare under sole re...