Bunn AutoPOD Installation & Operating Manual

Summary of AutoPOD

  • Page 1

    Installation & operating guide bunn-o-matic corporation post office box 3227 springfield, illinois 62708-3227 phone: (217) 529-6601 fax: (217) 529-6644 to ensure you have the latest revision of the operating manual, or to view the illustrated parts catalog, programming manual, or service manual, ple...

  • Page 2

    Page 2 41167.1 030912 bunn-o-matic commercial product warranty bunn-o-matic corp. (“bunn”) warrants equipment manufactured by it as follows: 1) airpots, thermal carafes, decanters, gpr servers, iced tea/coffee dispensers, mcp/mca pod brewers thermal servers and thermofresh servers (mechanical and di...

  • Page 3

    Page 3 41167.1 050312 contents warranty .............................................................................................................2 introduction ........................................................................................................3 user notices ....................

  • Page 4

    Page 4 electrical requirements caution - the brewer must be disconnected from the power source until specifi ed in initial set-up. Refer to data plate on the brewer, and local/national electrical codes to determine circuit requirements. Electrical hook-up caution – improper electrical installation w...

  • Page 5

    Page 5 plumbing requirements these brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kpa) from a ½˝ or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is gr...

  • Page 6

    Page 6 -1000 213.8 101.0 200 93.3 -500 212.9 100.5 200 93.3 0 212.0 100.0 200 93.3 500 211.1 99.5 200 93.3 1000 210.2 99.0 200 93.3 1500 209.3 98.5 200 93.3 2000 208.4 98.0 200 93.3 2500 207.4 97.4 200 93.3 3000 206.5 96.9 199 92.8 3500 205.6 96.4 198 92.2 4000 204.7 95.9 197 91.7 4500 203.8 95.4 19...

  • Page 7

    Page 7 41167.1 041410 coffee brewing 1. Place cup under brew chamber fig 8-1. (slide booster out for small cups) fig 8-3. 2. Press the open/close switch to open pod door fig 8-2. 3. Press fresh pod fi rmly down into pod holder fig 8-3. 4. Press the open/close switch to close pod door fig 8-2. 5. Pre...

  • Page 8

    Page 8 sprayhead 1. Open the pod door with the "open/close" switch. 2. Disconnect brewer from power source and allow to cool. 3. Unscrew sprayhead counterclockwise (looking from below). Fig 8-1 4. Remove sprayhead and seal from holder. 5. Check and clean the sprayhead. The sprayhead holes must alway...

  • Page 9

    Page 9 tank draining factory blowout 1. Disconnect the power and water supply to brewer. Allow brewer to cool before proceeding. 2. Remove 2 screws that secure the top cover. Remove the cover. Place brewer next to a sink. 3. Disconnect the hose from (top) center hose barb of each tank. Connect a pie...

  • Page 10

    Page 10 hidden switch step forward through screens open/close "no" or (-) large brew (a) "done" hot water "yes" or (+) small brew (b) step backwards through screens programming switches hidden switch press until display reads "brew lockout" st stee 41167.1 051508.

  • Page 11

    Page 11 program overview brew lockout (yes/no) setting to "yes" will only allow brews at or above the "set ready" temp screen. Brew type (a/b) (tea/coffee) tea setting provides less "purge" after brew cycle. Brew oz. (a/b) (1-16) adjust brew volume. Brew meter (a/b) (1-5) simplifi ed pulse brew adju...

  • Page 12

    Page 12 adjustments & optional settings brew oz a: 8.0 (-) done (+) enter password 0 0 0 brew lockout ? No done yes units metric done eng set language ? No yes enter service #? No yes brew type a tea done coffee brew meter a: 2 - + brew oz b: 6.0 (-) done (+) brew type b tea done coffee set password...

  • Page 13

    Page 13 air time a: 17.0 (-) done (+) air pump power 4 (-) done (+) enabl energysavr no done yes brews to empty (-) 25 (+) drip t i m e a: 5 (-) done (+) setpulsebrew a ? No done yes adjustments & optional settings (cont.) calibrate flow ? No yes brew count ## reset next brew count ## no yes air tim...