C&K Systems ST800L+ Installation Manual

Other manuals for ST800L+: User Manual
Manual is about: SECURIT 800L+ CONTROL PANEL

Summary of ST800L+

  • Page 1

    Installation manual securit 800l+ control panel st800l+.

  • Page 2

    2 contents warnings 3 standards 3 warranty statement 3 product description 3 available parts 3 intended use 3 specifications 4 installation 5 mounting 5 wiring the control panel 5 mounting a remote keypad 7 wiring a remote keypad 7 powering up 7 initial power up 7 programming 8 exit time 8 entry tim...

  • Page 3

    3 warnings prolonged short circuit of any supply can cause damage to the unit. Take the necessary precautions in not allowing liquids to spill on or into the unit. Standards this unit conforms to ecd 89/336/eec & lvd 73/23/eec. It has been tested and proven to meet all current emission and immunity ...

  • Page 4

    4 specifications the following information explains the specifications of the panel. Specification for software revision number v2.0 the software revision number is located on the top of the main processor. Specification power supply mains supply voltage 230 v ac nominal psu output voltage 13.7 v no...

  • Page 5

    5 installation locate the control panel out of sight, such as in a hall, or under stairs or a cupboard, where connection is easy and the detector zone and mains cables can be concealed. Avoid areas subject to high temperature or humidity, such as next to a boiler/heater, in an airing-cupboard, or co...

  • Page 6

    6 detector reset (l+ when programmed for id) some detectors require the removal of power to reset (such as viper plus® or smoke detectors). You can program the l+ terminal to be used as an id output using option 7-4. The l+ terminal should then be used as the negative supply for these devices. The p...

  • Page 7

    7 mounting a remote keypad 1 choose the keypad location, and then mark holes for mounting. 2 make sure the cable is run through the backbox. 3 screw the backbox in the selected position, making sure the cable is not twisted. Wiring a remote keypad use 6 core cable for connection of all remote keypad...

  • Page 8

    8 if no programming is required, close any lids that are open and press the # key. This exits engineering mode. Then refer to the users manual for customer options. If at any time you want to exit engineering mode, confirm any options you have selected with the * (star) key. Then close all tamper ci...

  • Page 9

    9 sounder duration 3-2 (range 3-20 minutes) enter 3-2. The factory default is 15 minutes. You can program a new time by entering one key from the following table. Enter 1 3 minutes. Led 1 on. Enter 2 4 minutes. Led 2 on. Enter 3 5 minutes. Led 3 on. Enter 4 10 minutes. Led 4 on. Enter 5 15 minutes. ...

  • Page 10

    10 circuit programming 4 (range 2-7) you can program circuits 2-7 to suit your requirements. Circuit 1 is fixed as a final exit circuit. Circuit 8 has limited options. Enter program zone enter program zone 4 - 2 2 4 - 6 6 4 - 3 3 4 - 7 7 4 - 4 4 4 - 8 8 4 - 5 5 select the circuit you want to alter. ...

  • Page 11

    11 by pressing the keys 1-8 on the keypad, you can select which zones to be isolated during home set. As you press a key, its relevant led on the display toggles on or off. Any leds that are on are isolated during home set, and any that are off remain active. Engineer access code 1-1 the default eng...

  • Page 12

    12 factory programming defaults 9-9 restoring programming defaults enter 9-9. The sounder gives a rapid pipping sound. Wait for 5 seconds. An accept tone sounds, and the factory programming defaults are restored. The user and engineer codes do not change. Note: if any keys are pressed, this procedur...

  • Page 13

    13 entry circuit starts the entry timer when activated providing the panel is set. Fire (for use with smoke detectors) a zone that when activated emits an ascending sound from any internal speakers. If the panel is set, external sirens and strobes also sound, but in an unset state the external sound...

  • Page 14

    14 this information should be kept either inside the control panel or with the installer. It can be used to refer to programming details when needed. Zone zone use / location resistance keys entered 1 Ω 2 Ω 3 Ω 4 Ω 5 Ω 6 Ω 7 Ω 8 Ω timer value keys entered full seconds night seconds ext sounder minut...

  • Page 15

    15 fault finding a selection of common known problems and solutions are listed below. Problem cause answer programmed 7-5 but zone 1 won’t isolate in night set. Have not manually isolated zone when setting panel. When night setting enter code * 0 * 1. Tamper won’t clear with lid on. Tamper loop open...

  • Page 16

    C & k is a registered trademark of c & k components, inc. Copyright 1999 c & k systems, inc. P/n 5-051-613-00 rev a c e r t if ied c o m pa n y hkqaa approved certificate no cc106 please note: c & k systems is always endeavouring to improve quality and specification of all its products and may alter...