SOUNDER DURATION 3-2 (Range 3-20 minutes)
Enter 3-2. The factory default is 15 minutes. You can program a new time by
entering one key from the following table.
Enter 1
3 minutes. LED 1 on.
Enter 2
4 minutes. LED 2 on.
Enter 3
5 minutes. LED 3 on.
Enter 4
10 minutes. LED 4 on.
Enter 5
15 minutes. LED 5 on. (default)
Enter 6
20 minutes. LED 6 on.
Press * to confirm the selection. The accept tone then sounds.
NIGHT SET/HOME SET EXIT TIME 3-3 (Range 0-90 seconds)
Enter 3-3. The factory default is 15 seconds. You can program a new time
by entering one key from the following table.
Enter 0
0 Seconds. All LEDs off (Instant).
Enter 1
10 Seconds. LED 1 on.
Enter 2
15 Seconds. LED 2 on. (default)
Enter 3
30 Seconds. LED 3 on.
Enter 4
45 Seconds. LED 4 on.
Enter 5
60 Seconds. LED 5 on.
Enter 6
90 Seconds. LED 6 on.
Press * to confirm the selection. The accept tone then sounds.
Note: If extension speakers are fitted in Night and Home set, you can alter
the exit sounder volume by the control on the PCB marked VOLUME.
Option
Option
Results from choosing option no.
Code
Description
0
1
2
3
4
5
6
3-0
Exit Time (secs)
10
15
30
45
60
90
3-1
Entry Time (secs)
10
15
30
45
60
90
3-2
Sounder Duration (mins)
3
4
5
10
15
20
3-3
Night / Home Exit (secs)
0
10
15
30
45
60
90
After you enter the user code, the sounder starts at the lower controlled
volume. The volume increases after 5 seconds if Night or Home set are not
selected.
Examples
Change the full set Exit Time to 60 seconds
ENTER THIS
3-0
5
*
Description
Choose Full Set
Select 60 seconds
Confirm selection
Change the Sounder Duration to 3 minutes
ENTER THIS
3-2
1
*
Description
Choose Sounder
Select 3 minutes
Confirm selection
Change the Entry Time to 45 seconds
ENTER THIS
3-1
4
*
Description
Choose Entry
Select 45 seconds
Confirm selection
SUMMARY
NIGHT/HOME
SET EXIT
TIMER
SOUNDER
DURATION