    903number smartswitch 9000 9f426-03 user’s guide.

  • Page 3: Notice

    I notice notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, firmware, or soft...

  • Page 4: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 5: Doc Notice

    Iii notice doc notice this digital apparatus does not exceed the class a limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the canadian department of communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant l...

  • Page 6: Safety Information

    Notice iv safety information class 1 laser transceivers the fpim-05 and fpim-07 are class 1 laser products the fpim-05 and fpim-07 use class 1 laser transceivers. Read the following safety information before installing or operating these adapters. The class 1 laser transceivers use an optical feedba...

  • Page 7: Safety Information

    V notice safety information class 1 laser transceivers laser radiation and connectors when the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dbm or 55 x 10 -6 watts. Removing the optical c...

  • Page 8

    Notice vi declaration of conformity application of council directive(s): 89/336/eec 73/23/eec manufacturer’s name: cabletron systems, inc. Manufacturer’s address: 35 industrial way po box 5005 rochester, nh 03867 european representative name: mr. J. Solari european representative address: cabletron ...

  • Page 9: Contents

    Vii contents chapter 1 introduction features........................................................................................................................... 1-1 related manuals............................................................................................................ 1-4 ...

  • Page 10

    Contents viii appendix a fpim specifications fpim-00 and fpim-01..................................................................................................A-1 fpim-02 and fpim-04..................................................................................................A-2 fpim-05 and f...

  • Page 11: Chapter 1

    1-1 chapter 1 introduction the 9f426-03 fddi smartswitch ® module, shown in figure 1-1, is a four port switch module with three front panel fddi interfaces and one inb-2 backplane interface. The external fddi networks are connected to the module using standard cabletron fpims on the front panel. The...

  • Page 12

    Introduction 1-2 cabletron enterprise mibs. In addition, the front panel provides leds for fddi link status per port, as well as transmit and receive activity. Full duplex the 9f426-03 may be configured to operate in either simplex or full duplex mode. This is selected though local management or via...

  • Page 13

    1-3 introduction figure 1-1. The 9f426-03 module smb cpu inb 9f426-03 fddi.

  • Page 14: Related Manuals

    Introduction 1-4 related manuals the manuals listed below should be used to supplement the procedures and technical data contained in this manual. Smartswitch 9000 installation guide smartswitch 9000 9c300-1 environmental module user’s guide smartswitch 9000 9c214-1 ac power supply user’s guide inb ...

  • Page 15: Chapter 2

    2-1 chapter 2 installing the smartswitch 9000 module this module uses fpims for the front panel connections. They are not shipped with the module and must be purchased separately. For more information on fpims, see appendix a . Unpacking the module 1. Carefully remove the module from the shipping bo...

  • Page 16: User Accessible Components

    Installing the smartswitch 9000 module 2-2 figure 2-1. Installing an fpim user accessible components figure 2-2 shows the various components that are accessible to the user. These consist of an eight-position dip switch (explained below), replaceable proms and sockets for ram. These will be used for...

  • Page 17

    2-3 installing the smartswitch 9000 module figure 2-2. User accessible components an eight-position dip switch is located on the module card as shown in figure 2-2. The function of the switches are listed in table 2-1. Smb-1 prom boot prom flash simm socket 1 2 3 4 5 6 7 8 local dram socket dip swit...

  • Page 18

    Installing the smartswitch 9000 module 2-4 see the cautions at the end of this table. Table 2-1. Function of dip switch switch function description 8 clear password 1 when toggled, this switch clears user-entered passwords stored in nvram, and restores the default passwords. Once reset you can use t...

  • Page 19: Chassis

    2-5 installing the smartswitch 9000 module installing the module into the smartswitch 9000 chassis to install the smartswitch 9000 module, follow the steps below: 1. Remove the blank panel covering the slot in which the module is being installed. All other slots must be covered, if other modules are...

  • Page 20

    Installing the smartswitch 9000 module 2-6 figure 2-3. Installing the 9f426-03 module metal back-panel module guides module jack for esd wrist strap plastic tab warning: ensure that the circuit card is between the card guides. Lock down the top and bottom plastic tabs at the same time, applying even...

  • Page 21: The Reset Switch

    2-7 installing the smartswitch 9000 module the reset switch the reset switch is located under the top plastic tab as shown in figure 2-4. Use the reset switch to reset the module’s processor, shutdown (power down) the module, and/or restart the module. • to reset the module’s i960 processor, press t...

  • Page 22

    Installing the smartswitch 9000 module 2-8.

  • Page 23: Chapter 3

    3-1 chapter 3 operation the 9f426-03 fddi smartswitch module is a four port switch module with three front panel fddi interfaces and one inb-2 backplane interface. As shown in figure 3-1, packets are received at the front panel fddi ports and the inb-2 bus. These packets are converted into canonical...

  • Page 24: System Diagnostic Controller

    Operation 3-2 smb-1 bus the smb-1 is a 1mbs management bus located within the smartswitch 9000. This bus is utilized by all diagnostic controllers in the system including connectivity modules, power supply modules and the environmental module. The smb-1 transports inter-chassis information between s...

  • Page 25: Inb Interface

    3-3 operation inb interface each module that attaches to the inb has an inb network interface block (nib). The inb nib converts canonical frames to fixed length data blocks for transmission onto the inb. For data blocks received from the inb, the inb nib reassembles the data blocks received from the...

  • Page 26: I960 Core

    Operation 3-4 i960 core the i960 core provides the snmp protocol stacks to support industry standard mibs. Additionally, cabletron enterprise extension mibs are supported for each media type. Advanced management services, such as the distributed lan monitor, telnet and network address to mac address...

  • Page 27: Chapter 4

    4-1 chapter 4 lanview leds the front panel lanview leds indicate the status of the module and may be used as an aid in troubleshooting. Shown in figure 4-1 is the lanview leds of the 9f426-03 module. Figure 4-1. The lanview leds smb cpu inb 9f426-03 fddi inb transmit fddi status inb receive fddi rec...

  • Page 28

    Lanview leds 4-2 the functions of the two system status leds, system management bus (smb) and the cpu, are listed in table 4-1. The functions of the inb receive led are listed in table 4-2. The functions of the inb transmit led are listed in table 4-3. Table 4-1. System status (smb and cpu) leds led...

  • Page 29

    4-3 lanview leds the functions of the fddi receive leds are listed in table 4-4. The functions of the fddi transmit leds are listed in table 4-5. The fddi status leds display the status when bridging to the front panel port. The “a” and “b” leds indicate the status of the a and b ports. The “p” and ...

  • Page 30

    Lanview leds 4-4 the functions of the fddi status leds are listed in table 4-6. Table 4-6. Fddi status leds a p s b state green n/a n/a green ports enabled and pcm active green green off green thru a green off green green thru b green green yellow yellow wrap a yellow green yellow green wrap b green...

  • Page 31: Chapter 5

    5-1 chapter 5 specifications technical specifications cpu intel i960 risc based microprocessor memory 4 meg. Flash memory (expandable to 32 meg.) 16 meg. Dram standards ansi fddi x3t9.5 smt mac phy mmf-pmd smf-pmd network interface cabletron fpims.

  • Page 32

    Specifications 5-2 safety this equipment meets the safety requirements of: • ul 1950 • csa c22.2 no. 950 • en 60950 • iec 950 • emi requirements of fcc part 15 class a • en 55022 class a • vcci class i • emc requirements of: en 50082-1 iec 801-2 esd iec 801-3 radiated susceptibility iec 801-4 eft se...

  • Page 33: Fpim Specifications

    A-1 a fpim specifications this smartswitch 9000 module uses fiber port interface modules (fpim) to provide front panel cable connections. The fpims are user-installable. See section titled installing an fpim on page 2-1. Fpim-00 and fpim-01 the fpim-00 and fpim-01 provide a multimode fiber connectio...

  • Page 34: Fpim-02 and Fpim-04

    Fpim specifications a-2 transmitter power parameters are listed in table a-2. The link distance is up to 2 kilometers on the multimode fiber-optic cable as specified by ansi mmf-pmd. Fpim-02 and fpim-04 the fpim-02 has an rj-45 connector supporting an unshielded twisted pair (utp) connection. The fp...

  • Page 35: Fpim-05 and Fpim-07

    A-3 fpim-05 and fpim-07 fpim-05 and fpim-07 the fpim-05 and fpim-07 provide a single-mode fiber connection. The fpim-05 uses a mic-style connector and the fpim-07 uses an sc-type connector. The specifications for both devices are listed in table a-4. The link distance is up to 40 kilometers (max) an...