Cabletron Systems MR-9000TPT User Manual - page 10
Page 2-2
Minimum packet
repeated:
96 bits including preamble. Packet
fragments are extended using the
JAM (1,0) data pattern.
FAULT protection:
Segment disconnect occurs after 32
consecutive collisions, or when a
segment’s collision detector is on for
longer than 2 to 3 ms. FAULT
protection resets automatically after
one packet is transmitted onto the
FAULT protected segment without
causing a collision.
RJ-45 Interface (Port 1 - 8)
Transmitter
Bandwidth:
15.0 MHz normal; 13.5 to 16.5 MHz
worst case
Signal amplitude
(balanced):
2.2 V normal; 1.8 to 2.6 V worst case
Idle signal frequency: 1.0 MHz normal; 0.9 to 1.1 MHz worst
case
Idle turn-on delay:
1200 ns normal; 1000 to 1400 ns worst
case
Output impedance:
100 ohm normal; 90 to 110 ohm worst
case
Receiver
Receive threshold:
320 mV
Data frequency:
3.5 to 12 Mb/sec
Common mode
rejection ratio:
Greater than 65 dB
Near end crosstalk:
-23 dB max.
Input impedance:
100 ohm normal; 90 to 110 ohm worst
case
Internal transceiver:
Cabletron Systems TPT-2 transceiver
SPECIFICATIONS AND REQUIREMENTS