CableTronix CT-SAW860 Installation Manual - page 4
1. UNPACKING and HANDLING
Each unit is shipped with all equipment assembled, and factory tested.
Ensure that all accessories are removed from the container before discarding packing
material
2. MECHANICAL
INSPECTION
Inspect the front and rear of the equipment for shipping damage. Make sure the equipment is
clean, and no connectors are broken, damaged, or loose. If equipment appears to be
damaged or defective please contact us at 1-610-429-1511 for assistance.
3. PRODUCT
DIAGRAM
c d e f g h i
j k l
11 12
1
Power
“Power-On” indicator light
2
Channel
Preset Channel
3
Output Test
The input signal is tapped down –30dB for monitoring.
Test port must be terminated when not in use
4
Output Level
Simultaneously adjusts amplitude of aural and visual
carriers
5
Audio Level
Adjusts for 25KHz peak deviation
6
Aural Level
Controls amplitude of aural RF carrier to change
aural/video ratio
7
Video Level
Adjusts depth of modulation when video level is greater
than 1.5Vp-p terminated signal
8
Video Input
F-connector accepts a video signal from a source such
as a satellite receiver, demodulator, or DVD player
9
Audio Input
F-connector accepts audio signal from a video source
such as a satellite receiver, demodulator, or DVD player
10
RF Output
The modulated output signal is available for distribution
from the F-connector
11
Convenience Outlet
Allows looping of power among units
12
Power Cord
For 120VAC, 60Hz
4