CADDX NX-148 Installation Manual - page 4
4
[
U
]-[9]-[2] PROGRAMMING CUSTOM MESSAGES IN THE KEYPAD
NOTES: The messages (custom, zone, and shutdown) are transferred to other LCD keypads after this mode is exited.
All keypads must be addressed and enrolled for this to happen. Set the keypad numbers with [
U
]-[9]-[4] prior
to programming custom messages. If a keypad is added after messages are programmed, you should either program
ALL messages in it, or enter custom message programming on an existing keypad and make changes. This is to
prevent accidentally overwriting existing messages. See [
U
]-[9]-[3] option to prevent overwriting the custom message
only.
1) Enter [
U
]-[9]-[2]
The LCD Screen will prompt for the "Go To Program" code.
2) Enter [program code]
The LCD will now prompt you to enter message number followed by [#]. Zone 1
through 48 custom messages are message numbers 1-48 respectively.
Message 49 - Custom message top line.
Message 50 - Custom message bottom line.
Message 51 - Shutdown message top line.
Message 52 - Shutdown message bottom line.
3) Enter message number to
edit followed by [#]
The LCD will display the zone number on the top line and the description will be
shown on the bottom line. Use the instructions on page 2 for editing character data.
4) When completed, exit by pressing [EXIT] while the LCD screen is prompting for a zone message #. Any
changes will automatically be copied to all other LCD keypads in the system. NOTE: If you desire an LCD keypad
to have a different custom message, you must enable Custom Message Lock under the [
U
]-[9]-[3] function.
[
U
]-[9]-[3] SET KEYPAD OPTIONS
1) Enter [
U
]-[9]-[3]
The LCD Screen will prompt for a code.
2) Enter [program code]
The LCD will now prompt you through the options listed on the following chart. The
current state of the option will be shown in the lower right corner of the display.
Press [
U
] to exit the current state unchanged. Otherwise, follow the directions on
the bottom line to select the desired option. When finished, press [
U
] to move to the
next option.
OPT
KEYPAD FEATURES
1
NOT USED
2
SILENT KEYPAD? Enable Silent Keypad Option. If enabled, only the entry/exit and sounder chime are
silenced.
3
DING DONG CHIME? Enable Ding Dong Sound for Chime. If off, chime will be a single tone. (Refer
to NX-8 Installation manual, location 40)
4
5 SEC. SILENCE? Enable Keypress Silence Option. Silences the pulsing keypad sounder for 5
seconds when a key is pressed.
5
ARMED ZONE INFO? Enable Armed Zone Information. If on, the LCD keypad will display faulted or
bypassed zone information when the system is armed.
6
BEEP ON PANICS? Enable Panic, Fire, Medical Beeptone. Will sound a short beep to verify that the
keypress was accepted.
7
DISABLE SERVICE? Suppresses the "Service" Message. This will not allow the "Service" Message
to be displayed for any reason. If there is a system trouble, [
U
]-[2] will still show the "Service" menu.
8
MASTER KEYPAD? Enable Multi-partition Mode
9
CUSTOM MESSAGE? Enable Custom Message Display
10
CLOCK? Enable Clock Display
11
CUSTOM MSG. LOCK? Enable Custom Message Lock. Prevents over-writing the custom message
during keypad copy.