CAME A 3024 N Installation Manual - page 4
4
ENGLISH
Th
e data and inf
or
m
atio
n s
hown in this manual ma
y be changed b
y
C
A
M
E cancelli automatici s.p
.a
. at an
y time w
itho
ut pr
io
r war
ni
ng.
5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance
with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
N.B.: If the cable length differs from that specifi ed in the table, then you must determine the proper cable diameter in the basis of the
actual power draw by the connected devices and depending on the standards specifi ed in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw
and distances.
5.3 Cable list and minimum thickness
Connections
Type of cable
Length of cable 1 < 10 m
Leng. cable 10 < 20 m
Leng. cable 20 < 30 m
Control panel power supply 230V 2F
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Flashing light 24V
2 x 0,5 mm
2
2 x 1 mm
2
2 x 1,5 mm
2
Photocell transmitters
2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photocell receivers
4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
24V Accessories power supply
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Command buttons
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Endstop
3 x 0,5 mm
2
3 x 1 mm
2
3 x 1,5 mm
2
Encoder plug
2402C 22AWG
max. 30 m
Antenna connection
RG58
max. 50 m
1) Operator
2) Control panel
3) Radio receiver
4) Photocells
5.4 Standard installation
1
1
2
3
4
4
5
4
4
6
7
8
5) Selector switch
6) Antenna
7) Flashing light
8) Transmitter