7.5.5 Table-Based “Edlog” Dataloggers
1. Connect a single CS215 to the datalogger Control Port p as described in
Section 7.3, Wiring, and download a datalogger program that contains the
SDI-12 Recorder (Instruction 105) instruction with valid entries for each
parameter.
2. In the LoggerNet Toolbar, navigate to and activate the Tools|Terminal
Emulator … menu. The “Terminal Emulator” window will open. In the
Select Device menu, located in the lower left-hand side of the window,
select the station.
3. Click on the Open Terminal button. If communications between the
datalogger and PC are successful, the red bar located in the upper left-hand
side of the window will turn green.
4. Click inside the “Terminal Emulator” window and press the
until the TD datalogger responds with the “>” prompt.
5. To activate the SDI-12 Transparent Mode on Control Port p, enter
.8. The
TD datalogger will respond with a “
.” prompt. At the “.” prompt enter #.
The TD datalogger will respond with 150000. Finally, enter p (Control
Port p) and press the
entering SDI-12.
6. To query the CS215 for its current SDI-12 address, enter the command ?!.
The CS215 will respond with the current SDI-12 address.
7. To change the SDI-12 address, enter the command aAb!; where a is the
current address from the above step and b is the new address. The CS215
will change its address and the datalogger will exit the SDI-12 Transparent
Mode.
8. To activate the SDI-12 transparent mode, on Control Port p, enter
.8. The
TD datalogger will respond with a “
.” prompt. At the “.” prompt enter #.
The TD datalogger will respond with 150000. Finally, enter p (Control
Port p) and press the
entering SDI-12. Verify the new SDI-12 address by entering the ?!
command. The CS215 will respond with the new address.
9. To exit the SDI-12 Transparent Mode, type in
∗.
22