Symptom: Incorrect temperature or relative humidity
1. If 12V power is switched “on” for the measurement, verify the program is
allowing a “warm-up” time of at least 100 ms.
2. Check to see if the filter tip has been contaminated. Replace the filter tip
(PN 18142), or clean with distilled water as needed.
3. The specification for drift is 1% per year. Calibration can be checked by
temporarily installing a new sensing element and comparing readings to
those taken with the original element. Replace the element (PN 18144)
annually, or as needed.
10. References
AASC, 1985: The State Climatologist (1985) Publication of the American
Association of State Climatologists: Heights and Exposure Standards for
Sensors on Automated Weather Stations, v. 9, No. 4 October, 1985.
(www.stateclimate.org/publications/state-climatologist/NOAA-NCY-
SCBOOKS-SC77097/00000029.pdf)
EPA, 2008: Quality Assurance Handbook for Air Pollution Measurement
Systems, Vol. IV, Meteorological Measurements, Ver. 2.0, EPA-454/B-08-
002 (revised 2008). Office of Air Quality Planning and Standards,
Research Triangle Park, NC 27711.
Goff, J. A. and S. Gratch, 1946: Low-pressure properties of water from -160°
to 212°F, Trans. Amer. Soc. Heat. Vent. Eng., 51, 125-164.
Lowe, P. R., 1977: An approximating polynomial for the computation of
saturation vapor pressure, J. Appl. Meteor., 16, 100-103.
Meyer, S. J. and K. G. Hubbard, 1992: Nonfederal Automated Weather
Stations and Networks in the United States and Canada: A Preliminary
Survey, Bulletin Am. Meteor. Soc., 73, No. 4, 449-457.
Weiss, A., 1977: Algorithms for the calculation of moist air properties on a
hand calculator, Amer. Soc. Ag. Eng., 20, 1133-1136.
WMO, 2008. Guide to Meteorological Instruments and Methods of
Observation. World Meteorological Organization No. 8, 7th edition,
Geneva, Switzerland.