17
SPECIFICATIONS
Monitor diagonal:
4 inches
Monitor resolution:
160V x 128H
Monitor power consumption:
25mA with backlight off
55mA
with
backlight
on
Monitor Voltage requirements:
9-14VDC
Probe battery requirements:
4AA
Probe battery life:
Greater than 200 hours of run time
FAQ
Display will not turn on:
1. Verify that power is connected to the display and that the fuse is good.
2. Verify source voltage. The display will function on 9VDC to 14VDC. If the voltage is
out side this range the unit will not function.
3. The screen may be black and too hot to function. In this case immediately cover the
screen or turn it away from the sun.
Unit beeps but the screen stays blank or black:
1. LCD displays can turn black if they are operated in extreme temperatures. Make sure
that the display is allowed to cool down if it has been sitting in the sun on a hot day.
2. Verify the contrast setting. If you cannot read the display at all press the menu button
twice and attempt to adjust the contrast with the arrow keys.
Display power on but no data is displayed:
1. Verify that the batteries in the probe are in good working order.
2. Verify that the probe is connected to the uncoated portion of the downrigger cable.
3. Verify that the battery pack is installed in the probe correctly.
1. Battery polarity is marked on the plastic battery pack.
2. The battery pack can be installed in 2 different positions. If the battery pack is
positioned incorrectly the snap terminals will not align with the spring contacts in
the
probe.
4. The probe will turn on after it is placed in the water.
5. Verify boat ground. The system will work best if the ground (battery–) connected to the
monitor display is also in contact with the water. If this ground connection is not in
place you may not see data or the data may be inconsistent.