Canon DU7-1178-000 Service manual - page 90
Chapter 4
4-13
No response
#751
- Server has not booted
up.
- Network disconnected.
(If connection cannot be
made with transmission
destination, connection
is sometimes cut mid-
way.)
- Reset caused by
internal error.
Processing interrupted.
- Check transmission destination and network settings.
- Transmission jobs whose processing has stopped for
some reason or other are forced to quit by assigning an
internal error code (#751). As a result, after rebooting,
the job is not run.
TCP/IP error
#755
- IP address set to
0.0.0.0. In the following
two situations, the IP
address is 0.0.0.0.
1) Address could not be
obtained from DHCP,
BOOTP, RARP.
2) Unit launched in IP
fixed mode(keys 1+7 to
enter FIXIPmode).
- TCP/IP protocol stack
resources insufficient.
Even with internal retry
(5 times),transmission
failed.
- Set the IP address correctly or set DHCP, RARP,
BOOTP environments to operate properly.
- Turn power OFF/ON.
Check server
#801
- Error generated due to
cause on server side.
- SMB server side file
capacity not sufficient.
- In WindowsNT/2000
server, password was
incorrect.
- In WindowsNT SMB,
common file name did
not match.
- In SMB, a user exists
but no write privileges.
- SMB transmission
made to write-
prohibited file of the
same name.
- Reset server.
- Check server status and settings.
- Check the network traffic.
Cannot find server
#802
DNS/SMTP setting
error(DNS error)
Reprogramme the user mode settings. (domain name, E-
Mail address, DNS, mail server)
Check address
#804
- No match for specified
directory name.
- In SMB, a user exists
but no write privileges.
- Check that the destination directory name is correct.
- Set directory access privileges in the server.
Check address.
#806
- Wrongly specified user
name.
- Wrongly specified
password. (Excl.
Windows NT.)
- Change address book user name or password.
No messag
#807
No access rights for the
specified directory
- Check the access rights to the server.
Message
Error code Cause
Remedy