D-MAX DCC-500F User Manual - page 12
Please position the arrow to point to 'WHITE
BAL' on the SETUP menu by using the UP and
DOWN buttons
Please select the mode you wish to operate by
pressing the LEFT or RIGHT button.
- ATW(Auto Tracking White Balance) : This
mode can be used within the color temperature
range 1,800°K ~ 10,500°K (eg, fluorescent light,
outdoor, sodium vapor lamp or inside tunnels)
- AWC(Auto White Balance Control) : Please
press the SETUP button while the camera is
directed at a piece of white paper to obtain the
optimum state under current illumination. If the
environment including the light source is
changed you have to adjust the white balance
again.
- MANUAL : The manual adjustment mode
enables finer adjustment.
Please select ATW or AWC first. Please change
to manual adjustment mode and press the
SETUP button. Please set the appropriate color
temperature, and then increase or decrease the
red and blue color values while monitoring the
color changes on the object.
21
Please select 'MANUAL' mode if you wish to
adjust the shutter manually.
- You can select speed from '1/60' to
'1/120,000'sec (NTSC Models), '1/50' to
'1/120,000'sec (PAL Models).
Please press the SETUP button when all the
settings are complete.
While using the internal synchronous system, if
the shutter setting is on 'ESC' and the camera is
directly facing a bright fluorescent light, the
image on the screen can dirersely affected.
Therefore please choose the installation
location with care.
When 'MANUAL' mode is on, the SENS UP
function does not operate.
4) WHITE BALANCE
The screen color can be
adjusted by using the
WHITE BALANCE
function.
20
Note
SETUP
LENS MNUAL
SHUTTER
ESC
WHITE BAL
ATM
BACKLIGHT
OFF
AGC
LOW
DNR
LOW
SENS-UP
OFF
SPECIAL
EXIT