Da-Lite ADVANTAGE ELECTROL Instruction Book

Other manuals for ADVANTAGE ELECTROL: Instruction Book, Installer's Manual, Instruction Book, Instruction Book

Summary of ADVANTAGE ELECTROL

  • Page 1

    Da-lite screen company, inc. 3100 north detroit street post office box 137 warsaw, indiana 46581-0137 phone: 574-267-8101 800-622-3737 fax: 574-267-7804 toll free fax: 877-325-4832 www.Da-lite.Com e-mail: info@da-lite.Com instruction book for advantage® electrol® the da-lite difference..

  • Page 2: Save These Instructions

    If your screen was shipped with the motor and roller already installed, proceed to step 6. 1. Remove access door. First, remove the 2 screws from the ends. Be sure to support the door during this step to avoid injury. Then lift the door slightly and pull away from the edge of the case. 2. Carefully ...

  • Page 3

    2 advantage ® electrol ® installation 7-3/4" 6-1/16" 3/8" threaded rod (not included) attached to mounting bracket self-trimming flange 6-3/8" 7-3/4" finished ceiling 8" 6.42" 3/8" threaded rod (not supplied) hanger bracket see detail a 7.75" detail a 7.95" 3.41" electrical junction box motor end va...

  • Page 4

    3 advantage ® electrol ® installation for 120v screens up off down this switch can not be used with lvc. 120v wiring diagram for standard wall switch spdt switch with center off ac (common) ac hot 120vac 60hz 1 amp black/yellow black red whi te red (up) bla ck (d o wn) junction box located in left e...

  • Page 5

    Figure 5 120v wiring diagram with optional built-in low voltage control ground–must be connected to building ground rj-14 pin-outs (tab is facing up) important note: the wall switch is required to make any limit switch adjustments, even if a third party control system is used. Therefore, it is advis...

  • Page 6

    Low-voltage wall switch optional ir and rf remote control motor blue (common) brown (hot) green ground to case 240vac 50hz 240v wiring diagram with optional built-in low voltage control rj9 up stop down ground–must be connected to building ground rj9 green front back up dn gnd +5v 3-position switch ...

  • Page 7

    Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at da-lite. Should it be necessary to adjust for more or less drop of picture, proceed in the following manner: remove two screws to remove access door. Note: use a screw dri...

  • Page 8

    7 screen adjustment for 120v screens with a built-in low voltage control or vpi 1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. 2. Locate small 3-position switch on back of wall switch. See figure 5 for 120v screens or figure 8 for 220/240v screen...

  • Page 9

    Printed in u.S.A. 84214 rev. 12/09 8 troubleshooting symptom 1. Screen will not operate. Motor does not hum. 2. Screen does not stop at correct position. 3. Noise. Note: screen will operate with a low-pitched hum. 4. Coasting. 5. Fabric hangs crooked. Cause (a) incorrect line voltage. (b) blown fuse...

  • Page 10

    9.

  • Page 11

    10

  • Page 12

    Limited one year warranty on da-lite presentation products da-lite screen company, inc. Warrants its products to the original purchaser only, to be free from defects in materials and workmanship for a period of one (1) year from the date of purchase by the original purchaser provided they are proper...