Instruction book for tensioned large advantage ® electrol ®.
2 tools required for installation 1. The case provides multiple attachment points for bolts, cables, or threaded rod. Page 4 shows threaded rod installed. The variable position-mounting bracket may be located anywhere along the length of the case. It is recommended to keep the brackets spaced evenly...
3 if your screen was shipped with the motor and roller already installed proceed to step 7. 1. Remove the access door. First, remove the 2 bolts from each end with a 9/16" open wrench or socket driver. Next, use a 5/32" hex key to remove the two screws in the center of the access door. This will all...
4 tensioned large advantage ® electrol ® installation variable position mounting brackets electrical junction box electrical junction box screen roller access door audience side self-trimming flange 2 3/16" (suggested) 1/2" threaded rod (not included) attached to mounting bracket finished ceiling se...
5 1. Place operating switch in “down” position. 2. When the screen stops, turn the white “down” limit knob (figure 4) one-quarter turn counterclockwise. Test by raising picture surface approximately two feet, then lower again. Repeat until desired picture surface position is attained. Caution: do no...
6 120v wiring diagram with optional built-in low voltage control note: 20-24 awg wire recommended for connecting wall switch to low voltage controller. Caution: do not use 3-position high voltage rocker switch with this unit! This will damage the low voltage control board. Eye port: plug ir or rf re...
7 240v wiring diagram with optional built-in low voltage control note: 20-24 awg wire recommended for connecting wall switch to low voltage controller. Caution: do not use 3-position high voltage rocker switch with this unit! This will damage the low voltage control board. Eye port: plug ir or rf re...
8 troubleshooting visit www.Da-lite.Com/products/tutorials.Php to find installation and troubleshooting tutorials. You will also find a link to live chat for interactive support. You can contact us by email at info@da-lite.Com or by phone at 800.622.3737 or 574.267.8101 with any additional troublesh...
9.
10
11.
Limited five year warranty on da-lite tensioned advantage ® electrol ® , advantage ® electrol ® , tensioned large advantage ® electrol ® , large advantage ® electrol ® , tensioned contour ® electrol ® and contour ® electrol ® products only milestone av technologies llc warrants these da-lite branded...