Dacor ERV48 Installation Instructions Manual

Manual is about: renaissance downdraft vent

Summary of ERV48

  • Page 1

    Installation instructions downdraft raised vent models: erv30, erv36, erv48 prv30, prv36, prv46 part no. 65335 rev. L use these downdraft raised vents only with approved dacor ® appliances. See the installation instructions for the particular appliance model being installed to determine suitability..

  • Page 2

    Installation instructions .................................................... 8 installation preparation .................................................... 8 installation ........................................................................ 8 verifying proper operation ...........................

  • Page 3

    1 important information about safety instructions • the important safety instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or oper- ating this or any other appliance. •...

  • Page 4

    2 important safety instructions • do not install or operate a damaged appliance. If you receive a damaged appliance, contact your dealer or builder. • observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • for ge...

  • Page 5

    3 product dimensions product specifications 30 1/4" (76.8 cm) to 37 1/4" (94.6 cm) 1.0" (2.5 cm) 30" (76.2 cm) 18 5/8” (47.3 cm) 5/16” (8 mm) thick stiffener across back 3 3/4" (9.5 cm) 1" (2.5 cm) 28" 3-prong grounded power cord vent shown in raised position product data label motor cover front of ...

  • Page 6

    4 • the customer must supply 3 conductor wiring/conduit with minimum current carrying capacity of 8 amps. To supply power to the remote or in-line blower from the raised vent. See general system layout and planning the duct work for further details. • it is the owner’s responsibility to ensure that ...

  • Page 7

    5 installation specifications vertical non-combustible surface rear wall notches for self-rimming style installations, see range installation instructions notches required for some raised vent installations, see range installation instructions backsplash countertop overhang see the range installatio...

  • Page 8

    6 installation specifications • when connecting the duct work to the back of the unit, the customer must supply a 3 ¼” x 10” rectangular transition to make the connection. • for side and bottom exhaust connections, use the sup- plied atd2 transition to connect the duct work to the unit. It transitio...

  • Page 9

    7 • on side exhaust installations, allow five inches of space on the side for the adt2 exhaust transition plus addi- tional space for the duct attached to it (x). • make sure duct work does not interfere with floor joists or wall studs. • with concrete slab construction, “box-in” the duct work and b...

  • Page 10

    8 2. Cut and remove the foil material inside the knock-out hole. If you fail to remove the foil, the vent will not work. 3. If the unit will vent through the bottom or side: • attach the supplied atd2 transition to exhaust location with the provided sheet metal screws. • for bottom installations cut...

  • Page 11

    9 5. Gently slide the vent into the rear of the countertop cut- out with the electrical access panel toward the front. 6. Loosely attach the anchoring legs to the studs on the left and right sides of the raised vent using the provided keps nuts and washers. 7. Adjust the anchoring leg height so that...

  • Page 12

    10 installation instructions ground power input blower output electrical access panel raised vent electrical access panel raised vent front view to power wiring/conduit. Connect other end of wires to blower terminal block. Wires to power plug. Pre-wired at factory. Do not modify. Attach ground wire ...

  • Page 13

    11 installation instructions example of installation with bottom exhaust (side view) remp16 remote blower connect wires/conduit according to remote blower installation instructions floor raised vent range wiring/conduit from raised vent to remote blower see raised vent electrical access panel on fac...

  • Page 14

    12 installation instructions verifying proper operation warning • read the raised vent use and care manual completely before operation. • install all of the front filters prior to operating the raised vent. Refer to the use and care manual for filter instal- lation instructions. Caution to prevent d...

  • Page 15

    13 wiring diagram stud chassis ground ground power input blower output gnd l2 n1 l1 n2 gnd com com no no up limit switch down limit switch com nc no nc nc remote pot snorkel switch com n no relay speed control red red blue blue red blk orng orn g blk yel yel wht l bl k wht wht.