Dacor ERV36-ER Installation Instructions Manual

Manual is about: renaissance downdraft vent

Summary of ERV36-ER

  • Page 1

    Installation instructions downdraft raised vent models: erv36-er, erv48-er part no. 103106 rev. H use these downdraft raised vents only with approved dacor ® appliances. See the installation instructions for the particular appliance model being installed to determine suitability..

  • Page 2

    Installation instructions .................................................... 8 installation preparation .................................................... 8 installation ........................................................................ 8 verifying proper operation ...........................

  • Page 3

    1 important information about safety instructions the • important safety instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or oper- ating this or any other appliance. A...

  • Page 4

    2 important safety instructions do not install or operate a damaged appliance. If you • receive a damaged appliance, contact your dealer or builder. For general ventilating use only. Do not use to • exhaust hazardous or explosive materials and vapors. Use this raised vent only for its intended purpo...

  • Page 5

    3 product dimensions product specifications 30 ¼" (768 mm) to 37 ¼" (946 mm) 10" (254 mm) 30" (762 mm) 18 5/8” (473 mm) 5/16” (8 mm) thick stiffener across back 3 3/4" (95 mm) 1" (25 mm) 28" 3 prong grounded power cord vent shown in raised position product data label motor cover front of unit 6" (15...

  • Page 6

    4 planning the installation general system layout the vent system consists of the raised vent itself and a sin- gle dacor approved remote or in-line blower (see page 6). Warning failure to install an approved remote or in-line blower • or proper duct work will result in a back draft and/or the insuf...

  • Page 7

    5 installation specifications the raised vent exhaust may be configured to vent • through the back, the bottom or through one of the sides. The maximum allowable duct run must be taken into consideration when determining the layout. See planning the duct work for further details. Refer to the range ...

  • Page 8

    6 installation specifications when connecting the duct work to the back of the unit, • the customer must supply a 3 ¼” x 10” rectangular transition to make the connection. For side and bottom exhaust connections, use the sup- • plied atd2 transition to connect the duct work to the unit. It transitio...

  • Page 9

    7 on side exhaust installations, allow five inches of space • on the side for the adt2 exhaust transition plus addi- tional space for the duct attached to it (x). Make sure duct work does not interfere with floor joists • or wall studs. With concrete slab construction, “box-in” the duct work • and b...

  • Page 10

    8 cut and remove the foil material inside the knock-out 2. Hole. If you fail to remove the foil, the vent will not work. If the unit will vent through the bottom or side: 3. Attach the supplied atd2 transition to exhaust • location with the provided sheet metal screws. For bottom installations cut a...

  • Page 11

    9 gently slide the vent into the rear of the countertop cut- 5. Out with the electrical access panel toward the front. Loosely attach the anchoring legs to the studs on the 6. Left and right sides of the raised vent using the provided keps nuts and washers. Adjust the anchoring leg height so that th...

  • Page 12

    10 installation instructions ground power input blower output electrical access panel erv electrical access panel erv raised vent front view to power wires/conduit. Connect other end of wires to blower terminal block. Wires to power plug. Pre-wired at factory. Do not modify. Attach ground wire as sh...

  • Page 13

    11 installation instructions example of installation with bottom exhaust (side view) remp series remote blower connect wires/conduit according to remote blower installation instructions floor raised vent range wiring/conduit from erv to remote blower see erv electrical access panel on facing page ra...

  • Page 14

    12 installation instructions verifying proper operation warning read the raised vent use and care manual complete- • ly before operation. Install all of the front filters prior to operating the • raised vent. Refer to the use and care manual for fil- ter installation instructions. Caution to prevent...

  • Page 15

    13 wiring diagram stud chassis ground ground power input blower output gnd l2 n1 l1 n2 gnd com com no no up limit switch down limit switch com nc no nc nc remote pot snorkel switch com n no relay speed control red red blue blue red blk orng orn g blk yel yel wht l blk wht wht.

  • Page 16

    Dacor ● 600 anton blvd. Suite 1000 costa mesa, ca 92626 ● phone: (800) 793-0093 ● fax: (626) 403-3130 ● www.Dacor.Com.