Installation Specifications
The raised vent exhaust may be configured to vent
•
through the back, the bottom or through one of the
sides. The maximum allowable duct run must be taken
into consideration when determining the layout. See
Planning the Duct Work
for further details.
Refer to the range installation instructions for the mini-
•
mum cutout dimensions specific to the particular range
and ERV model being installed.
Install the raised vent and range so that they can be
•
removed if service is required.
The raised vent is equipped with adjustable anchor
•
legs to accommodate various cabinet heights.
Plan the installation so that all minimum dimensions
•
are met or exceeded. All contact surfaces between the
raised vent and any cabinets or walls must be solid and
at right angles.
Allow room for the exhaust duct coming out of the unit.
•
See
Planning the Duct Work
for further details.
Vertical
non-combustible
surface rear wall
Backsplash
Notch
Countertop
Overhang
See the range installation
instructions for exact countertop
and cabinet dimensions
Example of Layout with Bottom Exhaust
Example of Layout with Rear Exhaust
REMP series
remote blower
3 1/4” X 10” to
round transition
and 45°
adjustable elbow
Duct work between
raised vent and
remote blower
Wall board
Range
Backsplash
Raised vent
Raised vent
configured for
rear exhaust
Floor
Wiring/conduit
from raised vent
to remote blower
ILHSF series
in-line blower
3 1/4” X 10” to
round transition
Duct work
Duct work
Outside wall
Range
Wall cap on
outside wall
Raised vent
Raised vent
configured for
bottom exhaust
Floor
Wiring/conduit
from raised vent
to in-line blower
Cabinet back
All tolerances: +1/16”, -0, (1.6 mm,0) unless otherwise stated