Dacor Wall Ovens Installation Instructions Manual - page 4
Page 2
Page 3
STEP 2 (Continued)
Installation Planning
NOTE:
All dimensional tolerances are + 1/16”, - 0” unless otherwise stated.
31 1/4"
(794mm)
Recommended
(may be altered)
"B"
3"
24"
(610mm)
Minimum interior
cabinet depth
"A"
3/4" (19mm)
Support platform
(flush with cutout)
4"
"D"
Alternate
electrical
access
1" (25mm) Min.
clear to top of
doors for heat
exhaust
1
2
Recommended
electrical
access
Figure 1:
Single Wall Oven
Cutout Dimensions
1
3/4" (19mm)
Support platform
(flush with cutout)
Recommended
electrical
access
1" (25mm) Min.
clear to top of
doors for heat
exhaust
9 5/8"
(244mm)
Recommended
(may be altered)**
"B"
3"
4"
"A"
24"
(610mm)
Minimum interior
cabinet depth
"D"
Alternate
electrical
access
2
Figure 2:
Double Wall Oven
Cutout Dimensions
Figure 3:
Single Wall Oven installed under-counter
Cutout Dimensions
1 1/2" (38mm)
Typical counter top
36"
(915mm)
"A"
"C"
"B"
1
"D"
3"
4"
Electrical
access
3/4" (19mm)
Support platform
(flush with cutout)
1" (25mm) Minimum
to combustible floor
Table 1: Cutouts Dimensions
DACOR
Model number
ECS127
MCS127
ECS130
PCS130
MCS130
ECS136
ECS227
MCS227
ECD227
MCD227
ECS230
PCS230
MCS230
ECD230
PCD230
MCD230
Cutout
Width
“A”
25 1/2”
(648mm)
28 1/2”
(724mm)
34 1/2”
(876mm)
25 1/2”
(648mm)
28 1/2”
(724mm)
Cutout
Height
“B”
27 3/8”
(695mm)
27 3/4”
(705mm)
49 1/16”
(1246mm)
Minimum
cabinet
overall
depth
“C”
24”
(610mm)
Minimum
cabinet
width
“D”
27”
(686mm)
30”
(762mm)
36”
(914mm)
27”
(686mm)
30”
(762mm)
Electrical junction box may be located:
1. Above the oven cutout, to the right.
2. Below the oven platform, to the right.