E2v UNIIQA User Manual - page 23
U
SER
M
ANUAL
UNIIQA+
C
OLOR
–
R
EV
I
–
09/2016
P
A G E
|
23
7.4 Image Format
Sensor Mode (
SensorMode
) : Defines the number of pixels and their size. Only available for
versatile models.
This command is available in the CommCam “Image Format Control” section :
Read function (ASCII): “r smod”;
Returned by the camera : Integer from 0 to 3
Write function (ASCII): “w smod”
“0” : 4096 pixels, 5x5µm
“1” : 2048 pixels, 10x10µm
“2” : 1024 pixels, 10x10µm
“3” : 512 pixels, 10x10µm
GenCP address
ASCII
command
GenICam
command
Size R/W Description
0x12000
snsw
SensorWidth
4
R
Pixels number (can be set for versatile model)
-
-
SensorHeight
4
R
1
-
-
WidthMax
4
R
Pixels number (can be set for versatile model)
-
-
HeightMax
4
R
1
-
-
Height
4
R
1
-
-
Width
4
R
Pixels number (can be set for versatile model)
0x12004
smod
SensorMode
4
RW
Depending the model of the camera
0 : 4096 Pixels, 5x5µm
1 : 2048 pixels 10x10µm
2 : 1024 pixels 10x10µm
(Versatile only)
3 : 512 pixels 10x10µm
(Versatile only)
0x12008
revr
ReverseReading
4
RW
0 : disable
1 : enable
0x1200C
mode
OutputMode
4
RW
0 : Base 1 Output 24-bit
1 : Medium 2x output 24-bit (
High Speed only)
0x12010
clfq
OutputFrequency
4
RW
Configure the CameraLink Interface frequency
0 : 85MHz
1 : 60MHz
2 : 42.5 MHz
3 : 40 MHz
0x12014
srce
TestImageSelector
4
RW
0 : “Off” (Sensor image)
1: “GreyHorizontalRamp”
2 : “whitePattern”
3 : “GrayPattern”
4 : “BlackPattern”
5 : “GreyVerticalRampMoving”
0x12018
temp
Temperature
4
RO
Read temperature value
Format : Integer in degree Celsius
0x1201c
scdi
ScanDirection
4
RW
Set/Get Scan Direction (forward or reverse)
0: Forward
1: Reverse
2: Externally control by CC3 signal
o
CC3=0: Forward
o
CC3=1: Reverse