Eastern Tools & Equipment Liquid Propane Operation Manual - Out
6
Operation instruction of REDUCTOR ASSEMBLY
Instruction on LPG denser device (bottom)
To develop cold start performance of LPG generator unit, the air REDUCTOR ASSY includes one LPG
denser device (bottom), the detailed operation of the bottom is shown below.
When starting the cold LPG generator unit, open the valve of the LPG tank, close the resistance air
valve handle, press the LPG denser device (bottom) lightly, and hold for 1‐2 seconds, then stop.
Start the engine normally, and after finishing the start up, please open resistance air valve handle.
Parts
Included in with your unit are: (1) Flat head screwdriver, (1) Spark Plug Wrench, (1) 8 x 10 Wrench,
(1) 17x 19 wrench, (2) wheels, (1) axle, (1) handle bar, (1) leg stands
NO.
DESCRIPTION
Qty NO.
DESCRIPTION
Qty
1
High‐pressure intake
tube(1000mm)
1 5
Mix device( the same as carburetor)
1
2
REDUCTOR ASSY
1 6
LPG denser device (bottom)→mounted onto
REDUCTOR valve
1
3
TANK TOP COMP,FUEL
1 7
LPG air‐pressure adjusting bottom→mounted
onto REDUCTOR valve
1
4
Low‐pressure outlet tube
1
(1)
(2)
(3)
(4)
(5)
(6)
(7)
IN