TROUBLESHOOTING
S
YMPTOM
C
AUSE
R
EMEDY
Little or no airflow
1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring
5. Fuse blown
1. Tighten fan
2. Replace the fan motor
3. See Routine Maintenance Section
4. Check the wiring diagram to find
fault and repair
5. Replace the fuse or reset the circuit
breaker
Little or no water extraction
1. Insufficient air flow
2. Compressor fault
3. Loss of refrigerant gas
1. Check all of the above
2. Contact the Factory Service Center
3. Contact the Factory Service Center
Little or no defrost when
required
1. Faulty Timer
2. Faulty bypass valve
1. Contact the Factory Service Center
2. Contact the Factory Service Center
Unit vibrates excessively
1. Loose compressor mounts
2. Damaged fan
1. Tighten nuts on compressor mounts
2. Replace with a new fan
Water flooding inside
machine
1. Drain pipe blocked/frozen
2. Drain pipe too high
1. Clear the obstruction
2. Lower section of pipe