Eberspächer EasyStart T Installation Instructions Manual - Scope of Supply

Other manuals for EasyStart T: Operating Instructions Manual

Summary of EasyStart T

  • Page 1

    Easystart t installation instructions. Comfort timer with 7-day preset capability. 22 1000 32 88 07 08.2010

  • Page 2

    2 contents introduction page • please read first...................................................................................................... 3 • general information / safety instructions ................................................................. 3 • ”ventilate“ mode ...................

  • Page 3: Purpose

    3 introduction „ventilate“ mode if the symbol is not displayed in the menu bar, “ventilate” mode is only pos- sible in the heater for the heater models under certain prerequisites: • with the water heaters hydronic (b / d 4 w s, b / d 5 w s, b / d 4 w sc and b / d 5 w sc): the “heat / ventilate” swi...

  • Page 4: Scope of Supply

    4 scope of supply 1 12 v / 24 v timer 1 cap 1 fixing screw 1 base 1 flat connector housing 9 junior power timer push on sleeve 1 push on sleeve housing 2 locking clasps 1 drilling template additional parts (option) – room temperature sensor (order no.: 22 1000 32 49 00) – external temperature sensor...

  • Page 5: Installation

    5 installation install timer install the timer in a suitable place on the dashboard within the driver‘s line of vision and connect according to the sketch and circuit diagrams at the end of this documentation. • use the self-adhesive drilling template provided to position and drill the holes. Remove...

  • Page 6

    6 installation instructions electrical connection crimp the push on sleeves onto the heater lead harness (if necessary) and the room temperature sensor (optional) and tie into the 9-pin receptacle housing (see circuit diagrams at the end of these installation instructions). Push in the locking clasp...

  • Page 7: Easystart T Timer

    7 combine easystart t timer with easystart t timer mount one timer inside the vehicle as described on page 5 under „install timer“. Fix the second time in the same way, e.G. On the side or rear panel of the driver‘s or sleeper cabin and connect (see circuit diagrams at the end of the installation in...

  • Page 8

    8 initial commissioning perform initial commissioning the following steps must be performed consecutively during the initial commissioning. • apply operating voltage the operating voltage is applied by inserting the fuse in the fuse holder. Automatic detection five seconds after the operating voltag...

  • Page 9

    9 • configure system the system must be configured depending on the application. Press until the menu bar appears in the display and the temperature is displayed. Select symbol using or . Then briefly press and simultaneously. Confirm menu p1 with . Select the submenu c1 or c2 using or and confirm w...

  • Page 10

    10 initial commissioning configure system (continued) the data is transferred if the menu item c1 / 07 has been confirmed with . Then the time is displayed. The system configuration is finished. Notes on the menu items 04 • these menu items are not to be used for the current heaters and must be set ...

  • Page 11: Reset Function

    11 press until the menu bar appears in the display and the temperature is displayed. Select symbol using or . Then briefly press and simultaneously. Menu p1 is displayed. Select reset function using or and confirm with . The timer is reset to the factory settings. Miscellaneous please note! Reset fu...

  • Page 12: Displays

    12 what to do if …? Displays display • no diagnosis cable connected. • no diagnosis data available at present. Repeat query. Menu item does not appear in the menu bar • no unit with je diagnosis connected to the diagnosis cable. Menu item does not appear in the menu bar • ”ventilate“ mode has not be...

  • Page 13: Perform Heater Diagnosis

    13 diagnosis confirm symbol with . Heater is switched on. Confirm operating time with . And : simultaneously press briefly. The following actions are possible • call up error memory. Use or to call up the error memory f1 – f5. • call up error memory again. And : simultaneously press briefly. • delet...

  • Page 14: Display System Configuration

    14 display system configuration select submenu c2 as described on page 7. After they have been conformed with , the individual menu items are displayed step by step. Diagnosis 00 heater type 0 = unknown unit 1 = air heater 2 = water heater 3 = add-on unit 01 diagnosis 0 = – – – 1 = none 2 = free run...

  • Page 15: Parts List Circuit Diagrams

    15 parts list circuit diagrams 2.15.1 room temperature sensor (optional) 2.15.9 external temperature sensor (optional) 3.1.7 ”on / off“ button 3.1.9 ”heat / ventilate“ switch 3.1.11 ”round“ control unit 3.1.16 radio remote control button 3.1.17 ”mini controller“ control unit 3.2.15 easystart t timer...

  • Page 16

    16 circuit diagrams 25 2069 00 97 08 a parts list page 15 airtronic / airtronic m this circuit diagram is valid for heaters with one diagnosis cable and a control unit cable loom wich is firmly encapsulated. Please note!.

  • Page 17

    17 circuit diagrams 25 2069 00 97 09 a airtronic / airtronic m – adr this circuit diagram is valid for heaters with one diagnosis cable and a control unit cable loom wich is firmly encapsulated. Parts list page 15 please note!.

  • Page 18

    18 circuit diagrams 25 2361 00 97 03 a airtronic / airtronic m / airtronic l this circuit diagram is for heaters with 2 diagnostics cable and whose control box cable loom is wound with cable tape. Parts list page 15 please note!.

  • Page 19

    19 circuit diagrams 25 2361 00 97 04 a parts list page 15 airtronic / airtronic m / airtronic l – adr this circuit diagram is for heaters with 2 diagnostics cable and whose control box cable loom is wound with cable tape. Please note!.

  • Page 20

    20 circuit diagrams air heater d 8 lc 25 1890 00 97 03 a parts list page 15.

  • Page 21

    21 circuit diagrams air heaterd 8 lc parts list page 15 25 1890 00 97 03 a.

  • Page 22

    22 circuit diagrams hydronic b 4 w s / d 4 w s hydronic b 5 w s / d 5 w s hydronic b 4 w sc / d 4 w sc hydronic b 5 w sc / d 5 w sc 25 2217 00 97 03 a parts list page 15.

  • Page 23

    23 circuit diagrams hydronic d 5 w s / d 5 w sc – 24 v – adr 25 2218 00 97 01 a parts list page 15.

  • Page 24

    24 circuit diagrams hydronic m 25 2160 00 97 03 a parts list page 15.

  • Page 25

    25 circuit diagrams hydronic m – adr 25 2160 00 97 04 a parts list page 15.

  • Page 26

    26 hydronic l circuit diagrams 25 1818 00 97 05 a parts list page 15.

  • Page 27

    27 declaration of conformity.

  • Page 28: Www.Eberspaecher.Com

    W e r eserve the right to make changes printed in germany © j. Eberspächer gmbh & co. Kg j. Eberspächer gmbh & co. Kg eberspächerstraße 24 d-73730 esslingen telefon 0711 939-00 telefax 0711 939-0643 info@eberspaecher.Com www.Eberspaecher.Com.