Eberspächer EasyStart T Installation Instructions Manual - Easystart T Timer
7
Combine EasyStart T timer with
EasyStart T timer
Mount one timer inside the vehicle as
described on page 5 under „install timer“.
Fix the second time in the same way, e.g.
on the side or rear panel of the driver‘s
or sleeper cabin and connect (see circuit
diagrams at the end of the installation
instructions).
• If 2 timers are combined, the timer
with the connected heater cable loom
(universal design) and the connected
diagnosis cable (bl/ws) takes on the
master function, i. e all timer functions
and settings are possible.
The diagnosis query and settings in the
workshop menu are not possible with
the second timer.
Option
A room or external temperature sensor
can be connected for master detection
instead of the diagnosis cable (bl/ws)
(see circuit diagrams, Item 2.15.1 and
2.15.9).
• Note on heater models with two
diagnosis cables
(only for AIRTRONIC / AIRTRONIC M
and control units cable loom wound
with cable tape).
If a heater cable loom (universal design)
is not used for these heater models,
you must install a connection from the
diagnosis cable (bl/ge) in the 16-pin
heater connector S1, chamber 8 to the
timer, 9-pin connector S1, chamber 5.
•
Before starting up for the first time,
disconnect both timers from the power
supply for 5 seconds.
• The displays of the timers are automati-
cally aligned with each other.
Please note!