Ecotck Monica Plus Freestanding Installation Manual - Clearances to Combustibles
3
Installation Clearances & Specifications
Minimum clearances shown are in millimetres. All Ecoteck fires are tested to AS/NZS2918:2001.
Specifications were correct at time of printing but may alter and those detailed below should be used as
a guide only. Refer to the Installation and Operation Manual supplied with every Ecoteck Pellet Fire or
if in doubt, consult your Switch Retailer.
Clearances to Combustibles
B
J
H
A
E
External Flue
J
J
F
B
I
F
E
B
C
A
E
D
G
F
B
F
G
E
Internal Flue
Freestanding Clearances
* from shielded flue
Note:
AS/NZS 2918 requires a minimum of 100mm clearance for any side requiring access.
Note:
These are minimum clearances to combustibles. Actual installation distances may be greater.
Note:
The above clearance to combustibles on the flue are only applicable within the fire envelope. Clearance
outside this e.g.at a ceiling / wall thimble reverts to 25mm as per ARS flue test 05/1185.
Location
A
B
C*
D
E
F
G*
H
I*
J*
Dimension (mm)
50
150
50
~230
100
120
50
50
50
25