Propane Models:
(11 HP Honda Motor with 115V Electric Start)
To Start the Engine:
•
Turn on the main valve at the propane tank.
•
Check all connections for tightness and inspect for leaks. If you detect a gas odor, immediately shut off the main
fuel valve and consult a qualifi ed LP-gas service person or call EDCO directly. NEVER check for leaks using an
open fl ame; use a leak-testing solution. NEVER allow propane to escape in an enclosed area; propane is heavier
than air and will “settle”.
•
Tilt the machine back slightly to allow the disc to clear the slab surface.
•
Start the engine according to the directions in the engine manufacturer’s Owner’s Manual.
To Stop the Propane Model:
•
Tilt the machine back slightly to allow the disc to clear the slab surface.
•
Turn the engine off.
•
Close the valve on the propane tank.
Gasoline Models:
(11 HP Honda Engine)
To Start the Engine:
•
Tilt the machine back slightly to allow the disc to clear the slab surface.
•
Start the engine according to the directions in the engine manufacturer’s Owner’s Manual.
NOTE: If during operation refueling becomes necessary, allow the engine to cool down. NEVER refuel a hot engine.
To Stop the Gasoline Model:
•
Tilt the machine back slightly to allow the disc to clear the slab surface.
•
Turn the engine off.
Propane is extremely fl ammable.
To shut off the engine -
Press and hold the Emergency Stop Button
(Figure 3)
Figure 3