EMIX EMKP-8001 Operational Manual

Manual is about: 180 Zones Paging Microphone

Summary of EMKP-8001

  • Page 1

    1 operational manual emkp-8001 180 zones paging microphone version 1.4.

  • Page 2

    2 product overview the emkp-8001 is a 180 zones digital paging microphone. As the name digital paging microphone, emkp-8001 operates digitally. On each paging microphone it is possible to select 180zones with the possibility to connect up to 30 paging console by using single cat-5e extension cable. ...

  • Page 3

    3 features. • built-in microchip controller compile all the features into a single device • a lcd 4 x 20ch with blue back light to display system status, zones settings and grouping function • simple keypad layout make operation simple and user friendly • appropriate for a system less than 180zones....

  • Page 4

    4 top view and rear view figure 1.1 top view of the digital paging console figure 1.2 rear view of the paging console.

  • Page 5

    5 figure 1.3: bottom view of the digital paging microphone.

  • Page 6

    6 keypad and rear panel indication emkp-8001 digital paging microphone 1.1 keypad indicator 1 lcd display – 4 x 20 characters lcd to display system status & message easy for reading. Zones setting and zone grouping are displayed in multi pages for easy viewing 2 keypad – the large 24 labeled matrix ...

  • Page 7

    7 16 zone selection – to select zone within every page menu. 1 page contain 10zones for example 1 st page is zone 1 to zone 10, press page down (3) will be next 10 zones e.G. Zone 11 to zone 20. 1.2 rear panel indicator 17 mic sensitivity – to adjust microphone sensitivity. 18 communication port – t...

  • Page 8

    8 2.0 installation diagram / schematic diagram figure 1.3: there are 4nos of 180zones paging console connected up with 2nos of 12ch zone selector emzs-8012 through rj45 to line converter. All of the paging consoles have a loop through connection from the last paging console to zone selector. From th...

  • Page 9

    3.0 unit setup - zone configuration press zone button to enter zone setting figure: zone setting. By default, number of zone is set to 180 zones. Press page up or page down button figure: page down button pressed figure: page down button pressed again once total number of zone is confirmed you are a...

  • Page 10

    3.1 unit setup - delay (paging period timer) configuration the purpose of setting up the timeout delay to prevent the microphone accidently turned on and left unoccupied after an announcement has been made. Press delay button to enter delay period setting: press up or down button to select your time...

  • Page 11

    3.2 unit setup - chime configuration this unit has built-in 7type of different menu. Press chime button to enter chime setting: press up or down button to select your desire chime. Once confirm the chime setting by user, kindly chime configuration different chime, usually user given to choose their ...

  • Page 12

    3.3 unit setup - ptt configuration to select momentary (press to talk) or toggle press to on and press to off when the user used for paging. Press ptt button to enter paging mode configuration: press up or down button to select your toggle or momentary when paging. Once confirm the ptt setting press...

  • Page 13

    3.4 unit setup - priority configuration this is to set the priority level of the paging microphone. Priority. Press priority button to set device priority: once confirm the priority level setting press notes: manufacturing default setting will be always configuration level of the paging microphone. ...

  • Page 14

    3.5 unit setup - group save setting zone grouping consider a pre-configured action which means user can select the require zone and selected zone together. Enable easy access to a group of zone when paging. Kindly select the preferred channel where you wish to get press [save + no.1] button at the s...

  • Page 15

    3.7 unit setup - synchronize setting press sync button to synchronize device setting with other devices. Select for synchronize: press numeric keypad [no.1 or no.2] press no.1 button on the numeric keypad to synchronize group of zone for paging transfer to other linked up digital paging console exam...

  • Page 16

    4.0 - emergency (immediate) paging to do immediate paging, user has to press will be activated once emer button has been pressed: notes: this is the highest priority, no matter what is your paging console priority level setting was set the previous setting. 4.1 other - paging console paging console ...

  • Page 17

    17 technical specifications input voltage 24vdc max. Power consumption 100ma zoning capacity >180zones data communication rs485 protocol input connectors double rj-45, via cat-5 cable operation distance up to 1.2km data communication chimes settings 8nos type of chime selection display 4 x 20ch lcd ...

  • Page 18

    18 only emix technical service centers are allowed to make warranty repairs. Send the equipment directly to av electronics marketing sdn bhd, or contact us for a list of emix technical centers. This warranty is not valid if repairs are performed by unauthorized personnel or service centers. This war...

  • Page 19

    19 emix products must only be used for the purpose they were intended by the manufacturer and in conjunction with this operating manual. Av electronics marketing sdn bhd cannot accept any liability whatsoever for any loss or damages caused by service, maintenance or repair by unauthorized personnel,...

  • Page 20

    20 professional public address system www.Emix.Com.My.