EMIX EMKP-8001 Operational Manual - page 6
6
Keypad and Rear Panel Indication
EMKP-8001 Digital Paging Microphone
1.1 Keypad Indicator
1
LCD Display – 4 X 20 Characters LCD to display system status & message easy for reading. Zones setting
and zone grouping are displayed in multi pages for easy viewing
2
Keypad – The large 24 labeled matrix buttons make operation simple & user friendly.
3
Page Up – Navigation key for page menu and configuration selection. For example, current page is
zone 11 to zone 20, after button pressed will be switched to zone 1 to zone 10. For configuration
selection, the menu will be switched reversely when button pressed.
Used as primarily (next page) as parameter setting button too.
4
Page Down – Navigation key for page menu and configuration selection. For example, current page is
zone 1 to zone 10, after button pressed will be switched to zone 11 to zone 20. For configuration
selection, the menu will be switched forwardly when button pressed.
Used primarily (previous page) as parameter setting button too.
5
Emergency – To activate immediate paging. When button pressed, all zones will be selected
automatically.
6
Call – To activate paging after zone selection. Used as primarily (Enter) as parameter setting button
too.
7
Clear All – To clear all selected zone.
8
Priority – To enter priority setting menu.
9
Select All – To select all zones.
10
PTT – To enter paging mode configuration. 2 configurations are included which is Push to Talk
(momentary) mode and Toggle mode (Push to on & push to off).
11
Synchronize – To synchronize group memory or device setting.
12
Chime – To enter chime configuration. 7 types chime configuration included.
13
Save – To save zones group. Maximum 10 setting can be saved.
14
Delay – Delay (Paging countdown timer) is an added feature which able to prevent unwanted paging.
User might not deactivate the device after paging and this causes unwanted paging. By setting Delay,
the device will automatically deactivate when the delay period is time out.
15
Load – To load saved zones group. Maximum 10 setting can be loaded.