• Set the minutes by pressing the
(small
flame) button.
Setting P1 OFF Time
•
Briefly press SET button to scroll to setting P1
OFF time. P1
(moon) is displayed and the
time flashes.
•
Set the hour by pressing the
(large flame)
button.
• Set the minutes by pressing the
(small
flame) button.
Setting P2 ON Time
•
Briefly press
SET button to scroll to setting P2 ON time.
P2 (sun) is displayed and the time flashes.
•
See instructions SETTING P1 ON TIME.
Setting P2 OFF Time
•
Briefly press SET button to scroll to setting P2 OFF time.
P1
(moon) is displayed and the time flashes.
•
See instructions SETTING P1 OFF TIME.
• This concludes programming Timers P1 and P2. Press OFF
or wait. The handset will automatically save your changes.
MANUAL OPERATION
(Only possible, when MANUAL knob is used)
Access to the pilot burner is only required for ignition with a match.
When turning main valve knob, do not force. Knob has a slip clutch
that clicks until the end stops are reached. This allows for
manual flame height adjustment as well as adjustment to pilot
standby position.
1. Stop! Read the safety information included before proceed-
ing.
2. Turn main valve knob to the off, full clockwise
position.
3. Turn MANUAL knob to the man, full clockwise
position.
4. Place ON/OFF switch (if equipped) in O (OFF position).
5. Wait five (5) minutes to clear out any gas. Verify that no gas
is in the area around the appliance, including near the floor.
If you detect gas stop! Follow “What to do if you smell gas” in
the safety information on page 14. If no gas is present, pro-
ceed to step 6.
6. Place ON/OFF switch (if equipped) in I (On position).
7. With the MANUAL knob in man position a manual pilot valve
operator and piezo ignitor (optional) are accessible.
8. Fully push down manual pilot valve operator and hold in, to
start pilot gas flow (see figure 19, page 22).
Ignition with match:
Immediately light the pilot with a match, while continuing to
hold in the manual pilot valve operator for about one (1) min-
ute after the pilot is lit. Release manual pilot valve operator. If
pilot does not stay lit, wait five (5) minutes and repeat.
Ignition with piezo ignitor:
Change the ignition cable from the receiver to the valve (see
figure 19, page 22). Push in the piezo ignitor to ignite. If pilot
does not stay lit, wait five (5) minutes and repeat.
WARNING
If the pilot does not stay lit after several tries, turn the gas con-
trol knob (main valve knob) to OFF and proceed to step 12.
9. If applicable, replace pilot access panel before proceeding.
10. Turn MANUAL knob to the on, full counterclockwise
po-
sition.
11. Turn main valve knob to the full on, full
counterclock-
wise position.
12. If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE” (page 14).